DEVICE: SOZO Body Fluid Analyzer (B27727270000)
Device Identifier (DI) Information
SOZO Body Fluid Analyzer
2727000
In Commercial Distribution
2727000
IMPEDIMED LIMITED
2727000
In Commercial Distribution
2727000
IMPEDIMED LIMITED
SOZO Body Fluid Analyzer working in conjunction with SOZOapp is designed to provide real-time, noninvasive, radiation-free, multi-frequency measurement by applying and detecting a low-voltage electrical signal through the skin, via dry electrode, and displaying the results on a monitor.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
36022 | Bioelectrical body composition analyser |
An electronic device designed to estimate body composition (i.e., percent body fat, lean, bone, and/or hydration) with regards to bioelectrical impedance analysis (BIA) and often personal characteristics (e.g., age, gender, height, weight). It may be in the form of a unit with electrodes applied to the surface of the patient’s body, or a scale(s) placed on the floor and upon which the patient stands to measure total body weight. Both types perform BIA by passing a low electrical current through the body; personal characteristics may be manually entered. Data are analysed to provide measurements that may include body mass index (BMI), fat/muscle/bone mass, and total body water percent.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
OBH | Monitor, Extracellular Fluid, Lymphedema, Extremity |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K172122 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Humidity: between 15 and 93 Percent (%) Relative Humidity |
Handling Environment Temperature: between 5 and 40 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3f723a4f-5737-437c-877a-fd49bafa17d5
July 06, 2018
3
October 02, 2017
July 06, 2018
3
October 02, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
B27727270001 | 1 | B27727270000 | In Commercial Distribution | Carton | |
B27727270002 | 1 | B27727270001 | In Commercial Distribution | Outer shipper |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+61738603700
enquiries@impedimed.com
enquiries@impedimed.com