DEVICE: DELTRAN (H6719023270)

Device Identifier (DI) Information

DELTRAN
Custom
In Commercial Distribution
902-327
UTAH MEDICAL PRODUCTS, INC.
H6719023270
HIBCC

1
094651270 *Terms of Use
DELTRAN II, Disposable Pressure Transducer System, Neonatal 30cc/hr Flow Rate
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35511 Vascular catheter flush valve, continuous
A specialized, sterile, Y-piece device intended to be connected in an infusion line to an indwelling catheter and provide for the connection of a second infusion source. The second source usually serves to maintain a low keep vein open (KVO) flow in the catheter to prevent clotting. This device (the flush valve) may be equipped with a manually-operated mechanism to permit flushing of the line at a free-flow rate. This is a single-use device.
Active false
45275 Invasive blood pressure transducer set
A collection of devices that includes tubing, a pressure transducer(s), and other items [e.g., connectors, stopcock(s), clamps and filters] intended to be used for an invasive blood pressure measurement. This set will typically connect directly to the applied invasive catheter and the transducer will provide the electrical signals for display by a patient monitoring system. This device will have physical characteristics appropriate for preserving, to the extent possible, the waveform and fidelity of the measured pressure. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KRA Catheter, Continuous Flush
DRS Transducer, Blood-Pressure, Extravascular
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Flow Rate - 30 cc/hr
CLOSE

Device Record Status

ecedb274-3550-4708-aa8e-543ff85a7ab8
December 18, 2019
4
September 23, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
H6719023271 25 H6719023270 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
800-533-4984
customer@utahmed.com