DEVICE: EvenMore (H787103036110)

Device Identifier (DI) Information

EvenMore
10303611
Not in Commercial Distribution

ANGIODYNAMICS, INC.
H787103036110
HIBCC
May 27, 2021
1
079105071 *Terms of Use
14.5F x 20cm EvenMore Straight Hemodialysis Catheter (with Cuff 15cm from Tip)
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
37278 Double-lumen haemodialysis catheter, implantable
An implantable, flexible, double-lumen tube intended to be used for chronic or long-term (> 30 days) vascular access, primarily during haemodialysis, to conduct blood from a patient and returning it after extracorporeal circulation; it may also be used during haemoperfusion and/or apheresis. It is intended for coaxial flow of blood, may be radiopaque, coated with heparin to prevent thrombus formation, and/or include a silver-coated sleeve to retard bacterial growth; devices dedicated to catheter introduction/function (e.g., introducer needle) may be included.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MSD Catheter, hemodialysis, implanted
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K040402 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: less than 27 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Catheter Gauge: 14.5 French
Length: 20 Centimeter
CLOSE

Device Record Status

3bfcf750-5814-4c01-aaab-f55d77db1324
May 31, 2021
5
September 15, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
H787103036115 5 H787103036110 2021-05-27 Not in Commercial Distribution BOX
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(518)795-1676
dgreer@angiodynamics.com
CLOSE