DEVICE: ADx (H7878166381800)

Device Identifier (DI) Information

ADx
816638180
In Commercial Distribution

ANGIODYNAMICS, INC.
H7878166381800
HIBCC

1
079105071 *Terms of Use
GUIDEWIRE, PTFE 038 X 180CM FC 1.5MM J ROSEN
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58115 Peripheral vascular guidewire, manual
A long, thin wire intended to be percutaneously placed into the peripheral vasculature (not heart or central nervous system) to function as a guide for the introduction of devices (e.g., catheters). It is made of metal (e.g., stainless steel, Nitinol), with or without coating, and is available in a variety of distal tip designs. It is intended to be used for percutaneous angiography, angioplasty, rotational atherectomy and thrombectomy, drainage, and other diagnostic and interventional procedures. It may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQX Wire, guide, catheter
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 180 Centimeter
Device Size Text, specify: .038" x 180cm x 1.5mm J
Outer Diameter: 0.038 Inch
CLOSE

Device Record Status

8553267c-25bc-4059-b8ea-05daba8ed316
December 22, 2021
3
January 07, 2021
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
H7878166381801 10 H7878166381800 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
GS1 15051684019729
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(518)795-1676
dgreer@angiodynamics.com
CLOSE