DEVICE: DreamStation (00606959026032)

Device Identifier (DI) Information

DreamStation
DreamStation Auto BiPAP with Humidifier, AU
In Commercial Distribution
AUX700H15
Respironics, Inc.
00606959026032
GS1

1
080728314 *Terms of Use
DreamStation Auto BiPAP with Humidifier, Australia
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60712 Home BPAP unit
A portable mains electricity (AC-powered) device, which may include rechargeable batteries, intended to assist noninvasive ventilation (i.e., without use of an artificial airway) using bi-level positive airway pressure (BPAP) during spontaneous respiration for adult/child (non-infant) patients affected by obstructive sleep apnoea (OSA) and/or to treat patients with conditions requiring respiratory assistance in the home [e.g., chronic obstructive pulmonary disease (COPD)]. It is a small desktop unit with controls, and may include a built-in humidifier. The device is intended for use in the home but may also be used in healthcare facilities.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
BZD VENTILATOR, NON-CONTINUOUS (RESPIRATOR)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -4 and 140 Degrees Fahrenheit
Storage Environment Humidity: between 15 and 95 Percent (%) Relative Humidity
Storage Environment Temperature: between -20 and 60 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

3225d9c1-340d-4fb0-8177-7cb4f6539d51
February 06, 2023
5
August 21, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
+1(724)744-2500
respironics.service@philips.com
CLOSE