{"publicDeviceRecordKey":"3c0e0c75-3408-4fa3-a4a8-047fc903bc07","publicVersionStatus":"New","deviceRecordStatus":"Published","publicVersionNumber":1,"publicVersionDate":"2026-03-09T00:00:00.000Z","devicePublishDate":"2026-02-27T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"00763000936624","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Concerto Versa™","versionModelNumber":"CV-4-15","catalogNumber":null,"dunsNumber":"006261481","companyName":"MEDTRONIC, INC.","deviceCount":1,"deviceDescription":"COIL CONCERTO VERSA  CV-4-15","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"MR Conditional","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(800)633-8766","phoneExtension":null,"email":"Corporate.UDI@medtronic.com"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K253511","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"60941","gmdnPTName":"Non-neurovascular embolization coil","gmdnPTDefinition":"A non-bioabsorbable, implantable device intended to induce a thrombosis within a non-neurovascular blood vessel to treat an aneurysm and/or non-neurovascular arteriovenous malformation (AVM); it is not intended for neurovascular application. It is in the form of a metal or metal/synthetic polymer wire which coils upon deployment within an aneurysm or the vasculature surrounding a malformation; it is typically pre-attached to a nonimplantable delivery wire. Disposable devices associated with implantation (e.g., delivery wire, catheter) may be included.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"KRD","productCodeName":"Device, Vascular, for Promoting Embolization"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Coil Outer Diameter LARGE: 4 mm"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Coil Length: 15 cm"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Compatible Catheter Inner Diameter: 0.69-1.07 mm"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Coil Outer Diameter: 4.8 mm"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Implant Outer Diameter: 0.56 mm"}]},"environmentalConditions":{"storageHandling":[{"storageHandlingType":"Special Storage Condition, Specify","storageHandlingHigh":{"unit":"","value":""},"storageHandlingLow":{"unit":"","value":""},"storageHandlingSpecialConditionText":"Keep away from sunlight"},{"storageHandlingType":"Special Storage Condition, Specify","storageHandlingHigh":{"unit":"","value":""},"storageHandlingLow":{"unit":"","value":""},"storageHandlingSpecialConditionText":"Keep dry"}]},"sterilization":{"deviceSterile":true,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}