{"publicDeviceRecordKey":"9c574f1a-3550-45cc-904f-532c2e60651a","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":8,"publicVersionDate":"2025-12-16T00:00:00.000Z","devicePublishDate":"2018-09-11T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"00846468068356","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Zimmer® Cannulated Screw System","versionModelNumber":"00-1147-029-31","catalogNumber":"00-1147-029-31","dunsNumber":"793384496","companyName":"Pioneer Surgical Technology, Inc.","deviceCount":1,"deviceDescription":"Screw","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(906)226-9909","phoneExtension":null,"email":"regulatory@exalta.com"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K003496","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"66947","gmdnPTName":"Orthopaedic bone screw (non-sliding)","gmdnPTDefinition":"A small, threaded, non-bioabsorbable, implantable rod intended for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary stabilization of a fractured bone; it is not intended to be introduced through the sleeve of a femoral neck fixation plate/sleeve, not used in dentistry/orthodontics, craniofacial or spinal bones, and not dedicated to intramedullary fixation/arthrodesis. It is typically of cortical or cancellous design and has a drive (e.g., slot, cross, star, polygonal) at its proximal end for introduction with a screwdriver.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"HWC","productCodeName":"Screw, fixation, bone"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"3.0mm x 29mm x 1/2 Thread"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}