{"publicDeviceRecordKey":"69230d5e-767e-4edd-8d4b-e20caa939e4b","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":9,"publicVersionDate":"2026-02-09T00:00:00.000Z","devicePublishDate":"2016-09-15T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"00850291007017","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"FlowTriever Catheter, M","versionModelNumber":"10-102","catalogNumber":null,"dunsNumber":"076827459","companyName":"Inari Medical, Inc.","deviceCount":1,"deviceDescription":"FlowTriever Catheter, 14 mm","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"19496008433","phoneExtension":null,"email":"info@inarimedical.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"61779","gmdnPTName":"Thrombectomy wire-net","gmdnPTDefinition":"A device intended to be percutaneously introduced into the vasculature (coronary, peripheral and/or intracranial) through an appropriate intravascular catheter for the removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction; revascularization may also be achieved through thrombus reorientation. Also referred to as a stent retriever or clot retrieval catheter, it consists of an expanding, stent-like wire net connected to a pusher wire primarily intended to grip and remove the emboli/thrombi; it might include a guide-catheter dedicated to introduction of the wire-net. This is a single-use device.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"QEW","productCodeName":"Peripheral Mechanical Thrombectomy With Aspiration"},{"productCode":"KRA","productCodeName":"Catheter, Continuous Flush"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Outer Diameter","size":{"unit":"Millimeter","value":"14"},"sizeText":null,"sizeString":"Outer Diameter: 14 Millimeter"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":true,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}