{"publicDeviceRecordKey":"956fb120-3fb4-4f42-9e11-87eceb498f2e","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":2,"publicVersionDate":"2022-06-02T00:00:00.000Z","devicePublishDate":"2022-01-28T00:00:00.000Z","deviceCommDistributionEndDate":"2022-01-28T00:00:00.000Z","deviceCommDistributionStatus":"Not in Commercial Distribution","identifiers":{"identifier":[{"deviceId":"03661489710995","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"ARROW Short Stem Humeral System","versionModelNumber":"271099- ARROW TIGE DIAPHYSAIRE SANS CIMENT D6 L45","catalogNumber":null,"dunsNumber":"261839898","companyName":"FOURNITURES HOSPITALIERES INDUSTRIE","deviceCount":1,"deviceDescription":null,"DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":true,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":false,"otc":false,"contacts":{"customerContact":[]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K202024","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"39702","gmdnPTName":"Coated shoulder humeral stem prosthesis","gmdnPTDefinition":"A sterile implantable device designed to provide fixation within the proximal humerus and a site of attachment for a humeral head or humeral body prosthesis as part of a shoulder joint replacement. The device is made of metal [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] and is coated with a material (e.g., porous materials, hydroxyapatite) intended to improve fixation and stability by promoting bone ingrowth. Fixation devices for implantation (e.g., screws) may be included and implantation may be performed with or without bone cement.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"PHX","productCodeName":"Shoulder Prosthesis, Reverse Configuration"},{"productCode":"HSD","productCodeName":"Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented"},{"productCode":"KWS","productCodeName":"Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":true,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}