{"publicDeviceRecordKey":"341efe6b-e06e-49b4-869b-589823aca8a0","publicVersionStatus":"New","deviceRecordStatus":"Published","publicVersionNumber":1,"publicVersionDate":"2025-11-17T00:00:00.000Z","devicePublishDate":"2025-11-07T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"03662663108751","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"ST360 Spinal Fixation System","versionModelNumber":"07.00444.001","catalogNumber":"07.00444.001","dunsNumber":"119260394","companyName":"Highridge Medical, LLC","deviceCount":1,"deviceDescription":"Wrench Axial Torque","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":false,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":false,"otc":false,"contacts":{"customerContact":[{"phone":"+1(800)447-3625","phoneExtension":null,"email":"usbrocustomerservice@highridgemedical.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"47830","gmdnPTName":"Surgical instrument handle, torque-limiting","gmdnPTDefinition":"A hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, typically manual rotation of a bone screw or setscrew, whilst providing a torque-limiting function to ensure that the screw is not over tightened, during an orthopaedic procedure. The device is typically made of metal/synthetic material (e.g., polysulphone) and may have a T-shaped handle grip. It will normally provide an indication to the surgeon when the pre-set torque level is reached with an audible click and release of rotational traction. This is a reusable device.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"NKB","productCodeName":"Thoracolumbosacral pedicle screw system"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}