{"publicDeviceRecordKey":"82a533b3-b050-48c9-ad54-c12a608ddf9b","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":4,"publicVersionDate":"2020-07-30T00:00:00.000Z","devicePublishDate":"2016-09-23T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"04046963093976","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"AESCULAP","versionModelNumber":"PL530R","catalogNumber":"PL530R","dunsNumber":"315018218","companyName":"Aesculap AG","deviceCount":1,"deviceDescription":"Clip Applying/Removing Forceps, single-fire, (350 mm), diam. 12,50 mm, to be used with: PL541S, PL542S, PL543S, PL544S, PL545S, PL546S, PL547S, PL548S, PL549S","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(800)282-9000","phoneExtension":null,"email":"GUDID.BBMUS_Service@bbraun.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"35798","gmdnPTName":"Open-surgery ligation clip applier","gmdnPTDefinition":"A hand-held manual surgical instrument designed to apply small atraumatic clips (not included) for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may also be used to apply small clamps (e.g., bulldog type) to tissues however it is not intended to apply an aneurysm clip. The device is typically a metallic instrument with flat, curved ends to hold and deliver the clips (e.g., forceps-like); implantable clips are not included. This is a reusable device after sterilization.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"DXC","productCodeName":"CLAMP, VASCULAR"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Diameter (mm) : 12.500 MM"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Working length (mm) : 350.000 MM"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}