<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>e4403edd-9254-4cf9-8770-79df8d81c726</publicDeviceRecordKey><publicVersionStatus>New</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>1</publicVersionNumber><publicVersionDate>2020-08-10</publicVersionDate><devicePublishDate>2020-08-02</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>04046964566424</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>AESCULAP</brandName><versionModelNumber>MA695R</versionModelNumber><catalogNumber>MA695R</catalogNumber><dunsNumber>082594540</dunsNumber><companyName>AESCULAP, INC.</companyName><deviceCount>1</deviceCount><deviceDescription>BLAKESLEY Punch Forceps, angled, 7&quot;, (180 mm), working length: 4 1/4&quot;, (110 mm), #00, width: 2,50 mm, stainless steel</deviceDescription><DMExempt>false</DMExempt><premarketExempt>true</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>+1(800)282-9000</phone><phoneExtension xsi:nil="true"/><email>GUDID.BBMUS_Service@bbraun.com</email></customerContact></contacts><gmdnTerms><gmdn><gmdnCode>11775</gmdnCode><gmdnPTName>Open-surgery biopsy forceps, reusable</gmdnPTName><gmdnPTDefinition>A hand-held manual surgical instrument designed to obtain soft-tissue biopsy specimens from an open surgical wound or from within/near a large natural orifice (e.g., vagina, rectum) for histopathological examination; it is not intended for endoscopic or catheterized access. It is a metallic forceps-like instrument with a distal mechanism designed to bite/punch the biopsy sample and hold it for extraction when the handles are squeezed together. It is not designed for cutting bone (i.e., not a rongeur). This is a reusable device.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>KAE</productCode><productCodeName>FORCEPS, ENT</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>Working length (mm) : 110.000 MM</sizeText></deviceSize><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>Length : 180.000 MM</sizeText></deviceSize></deviceSizes><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>