DEVICE: ASCOT (04047844026236)

Device Identifier (DI) Information

ASCOT
Variable angle screw, self tapping
In Commercial Distribution
HV-4018
SIGNUS Medizintechnik GmbH
04047844026236
GS1

1
344203948 *Terms of Use
ASCOT® is an anterior cervical plate and screw system. Plates offered in a variety of sizes to accommodate anatomic requirements. Fixed and variable angle screws are available in numerous length/ diameter combinations. In addition, a center graft screw is offered.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46653 Spinal fixation plate, non-bioabsorbable
A small, implantable, non-customized sheet of solid material intended to be attached to the spine with screws for spinal immobilization; it is made of a material that is not chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). The device is typically used to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities (e.g., during anterior/posterior cervical, anterior/posterior lumbar, thoracolumbar, and occipital fixation procedures).
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KWQ Appliance, Fixation, Spinal Intervertebral Body
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K132310 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 0 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Ø4,0x18mm
CLOSE

Device Record Status

46d5b0c7-119d-44de-9660-228b5f796d31
September 18, 2023
6
September 24, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
+49602391660
info@signus.com