DEVICE: OTSC Anchor 220tt (04260206310297)

Download: XML | JSON

Device Identifier (DI) Information

OTSC Anchor 220tt
220 cm
200.11
Ovesco Endoscopy AG
04260206310297
GS1
1
The OTSC Anchor 220tt is one of the OTSC application aids • can be used for treating a lesion before release of the OTSC clip • can be used for better approximation of tissue especially when indurated (e.g. fistulae, chronic ulcer) • facilitates targeting lesions, e.g. in the treatment of hemorrhage • allows precise alignment between the target tissue and the application cap • the head of the instrument is made of Nitinol • a working channel diameter of at least 3.2 mm is required when used in combination with the OTSC System
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN Names and Definitions: © Copyright GMDN Agency 2015. Reproduced with Permission from the GMDN Agency.

GMDN Preferred Term Name GMDN Definition
Flexible endoscopic grasping forceps, single-use A flexible manual device intended to be used in combination with a compatible endoscope to grasp tissue (typically atraumatically) or foreign bodies. It is typically constructed of a flexible metal coil or plastic tube whose distal end is equipped with a pair of scissors-like grasping tongs or claws which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a single-use device.
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KOA Surgical Instruments, G-U, Manual (And Accessories)
CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: needle width 9 mm / stitch depth 2-2.5 mm
Device Size Text, specify: working length 220 cm
Device Size Text, specify: working channel diameter 3.2 mm
CLOSE

Device Status

In Commercial Distribution
September 16, 2016

CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE