DEVICE: ABL80 SC80 (05700699456748)

Device Identifier (DI) Information

ABL80 SC80
945-674
In Commercial Distribution
945-674
Radiometer Medical ApS
05700699456748
GS1

1
308667539 *Terms of Use
SC80 300/15 Full, no GLU, QC3
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
52858 Multiple blood gas/haemoximetry/electrolyte analyte IVD, kit, multiple technologies
A collection of reagents and other associated materials intended to be used for the quantitative measurement of multiple blood gas, haemoximetry and/or electrolyte analytes in a clinical sample, using multiple technologies such as ion-selective electrode (ISE) and haemoximetry in a single analyser. Analytes detected may include partial pressure of oxygen (pO2), partial pressure of carbon dioxide (pCO2), pH, sodium, potassium, ionized calcium, chloride, glucose, lactate, total haemoglobin (totHb), haematocrit, and haemoglobin derivatives such as reduced haemoglobin (RHb), methaemoglobin (MetHb), sulfhaemoglobin (SHb).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
CHL ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH
CEM ELECTRODE, ION SPECIFIC, POTASSIUM
JPI DEVICE, HEMATOCRIT MEASURING
JGS ELECTRODE, ION SPECIFIC, SODIUM
JJY Multi-analyte controls, all kinds (assayed)
CGA GLUCOSE OXIDASE, GLUCOSE
DQA Oximeter
JFP ELECTRODE, ION SPECIFIC, CALCIUM
GKR SYSTEM, HEMOGLOBIN, AUTOMATED
GHS ASSAY, CARBOXYHEMOGLOBIN
CGZ ELECTRODE, ION-SPECIFIC, CHLORIDE
JIX CALIBRATOR, MULTI-ANALYTE MIXTURE
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 5 and 25 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

97682d32-7755-4372-89a2-f49d11eb1992
November 27, 2020
3
September 01, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE