<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>fb332dcb-6a8e-40d4-93b7-4e35f83ccacd</publicDeviceRecordKey><publicVersionStatus>New</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>1</publicVersionNumber><publicVersionDate>2025-09-15</publicVersionDate><devicePublishDate>2025-09-06</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>08033390102773</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>SMR Shoulder</brandName><versionModelNumber>9013.74.652</versionModelNumber><catalogNumber>9013.74.652</catalogNumber><dunsNumber>432066322</dunsNumber><companyName>LIMACORPORATE SPA</companyName><deviceCount>1</deviceCount><deviceDescription>SMR Shoulder - Dia. 40-44mm Glenosphere Orienter RIGHT
</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><premarketSubmissions><premarketSubmission><submissionNumber>K243826</submissionNumber><supplementNumber>000</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>13180</gmdnCode><gmdnPTName>Orthopaedic prosthesis implantation positioning instrument, reusable</gmdnPTName><gmdnPTDefinition>A hand-held surgical instrument intended to be used during implantation of an orthopaedic prosthesis, either manually or as a computer-assisted surgery (CAS) device, to aid in the navigation/placement of the prosthesis or other instruments [e.g., drill sleeves and guide wires (Kirschner wires), patella saw guide]. It may be used for the following applications: 1) to hold/align/fix/guide other instruments, prostheses, or prosthesis components; 2) to provide relative position landmarks; 3) to ascertain correct spatial orientation or limb alignment; and/or 4) as an interface (non-adaptive) between prosthesis components. This is a reusable device intended to be sterilized prior to use.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>PHX</productCode><productCodeName>Shoulder Prosthesis, Reverse Configuration</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>Dia. 40-44mm RIGHT</sizeText></deviceSize></deviceSizes><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>