<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>6e8c034a-58c2-4259-81c3-fc8e1ccc3f1e</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>2</publicVersionNumber><publicVersionDate>2024-01-08</publicVersionDate><devicePublishDate>2020-07-16</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>08033390180733</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>AMF REVISION TT CONES</brandName><versionModelNumber>6C12.14.L21</versionModelNumber><catalogNumber>6C12.14.L21</catalogNumber><dunsNumber>432066322</dunsNumber><companyName>LIMACORPORATE SPA</companyName><deviceCount>1</deviceCount><deviceDescription>AMF Revision TT Cones - TT REV CONE Bicondylar Femur Dia. 21 mm - Left
</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><gmdnTerms><gmdn><gmdnCode>61556</gmdnCode><gmdnPTName>Sleeve femoral/tibial extension, coated</gmdnPTName><gmdnPTDefinition>A sterile implantable device typically designed to be attached to a revision femoral stem, knee femur prosthesis, femur/tibia shaft prosthesis, or body femoral/tibial extension stem to extend length to make up for bone loss during revision arthroplasty or bone resection. The device is a hollow sleeve made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel] and is coated with a material (e.g., porous materials, hydroxyapatite) intended to improve fixation and stability by promoting bone ingrowth. Fixation devices for implantation (e.g., screws and bolts) may be included.</gmdnPTDefinition><implantable>true</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>JWH</productCode><productCodeName>Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer</productCodeName></fdaProductCode><fdaProductCode><productCode>MBH</productCode><productCodeName>Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>Dia. 21 mm - Left</sizeText></deviceSize></deviceSizes><environmentalConditions/><sterilization><deviceSterile>true</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>