{"publicDeviceRecordKey":"5e154c88-f50c-4a1c-85ed-6b7cdd312449","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":3,"publicVersionDate":"2018-07-06T00:00:00.000Z","devicePublishDate":"2016-09-22T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"18033837190018","deviceIdType":"Package","deviceIdIssuingAgency":"GS1","containsDINumber":"08033837190011","pkgQuantity":1,"pkgDiscontinueDate":null,"pkgStatus":"In Commercial Distribution","pkgType":"X006528"},{"deviceId":"08033837190011","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"GIOTTO IMAGE 3DL","versionModelNumber":"GIOTTO IMAGE_20'' 3Mpixel","catalogNumber":"6909","dunsNumber":"429113525","companyName":"I.M.S. INTERNAZIONALE MEDICO SCIENTIFICA SRL","deviceCount":1,"deviceDescription":"GIOTTO IMAGE is a mammography unit with motorized tube rotation ± 240 for stereotactic biopsy.","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":false,"serialNumber":true,"manufacturingDate":true,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K111434","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"36513","gmdnPTName":"Mammographic x-ray system stereotactic unit","gmdnPTDefinition":"A device that can only fulfil its purpose when used together with and enhance the function of a diagnostic mammographic x-ray system. It is used to take two pictures of a breast from two different angles. On the basis of this stereoscopic picture set, it is possible to determine the exact position of a lesion in the breast and a cytological sample of this will be taken. This device or technique may be built-in to some diagnostic x-ray systems for mammography.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"MUE","productCodeName":"Full Field Digital,System,X-Ray,Mammographic"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Height","size":{"unit":"Millimeter","value":"2240"},"sizeText":null,"sizeString":"Height: 2240 Millimeter"},{"sizeType":"Depth","size":{"unit":"Millimeter","value":"1140"},"sizeText":null,"sizeString":"Depth: 1140 Millimeter"},{"sizeType":"Width","size":{"unit":"Millimeter","value":"1150"},"sizeText":null,"sizeString":"Width: 1150 Millimeter"}]},"environmentalConditions":{"storageHandling":[{"storageHandlingType":"Storage Environment Temperature","storageHandlingHigh":{"unit":"Degrees Celsius","value":"70"},"storageHandlingLow":{"unit":"Degrees Celsius","value":"-20"},"storageHandlingSpecialConditionText":null}]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}