<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>804b7039-88fb-448a-8f9e-9539a5a43ff1</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>5</publicVersionNumber><publicVersionDate>2021-07-13</publicVersionDate><devicePublishDate>2016-09-23</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>08426950058366</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>HemosIL Thrombin Time</brandName><versionModelNumber>00009758515</versionModelNumber><catalogNumber>00009758515</catalogNumber><dunsNumber>557223252</dunsNumber><companyName>INSTRUMENTATION LABORATORY COMPANY</companyName><deviceCount>1</deviceCount><deviceDescription>HemosIL Thrombin Time</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>true</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>1-800-678-0710</phone><phoneExtension xsi:nil="true"/><email>techsupport.na@werfen.com</email></customerContact></contacts><premarketSubmissions><premarketSubmission><submissionNumber>K862301</submissionNumber><supplementNumber>000</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>55987</gmdnCode><gmdnPTName>Thrombin time (TT) IVD, kit, clotting</gmdnPTName><gmdnPTDefinition>A collection of reagents and other associated materials intended to be used for the quantitative measurement of the thrombin time (TT) of a clinical specimen using a clotting method.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>GJA</productCode><productCodeName>TEST, THROMBIN TIME</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions><storageHandling><storageHandlingType>Special Storage Condition, Specify</storageHandlingType><storageHandlingHigh unit="" value=""/><storageHandlingLow unit="" value=""/><storageHandlingSpecialConditionText>Unopened reagents are stable until the expiration date shown on the vial when stored at 2-8°C</storageHandlingSpecialConditionText></storageHandling><storageHandling><storageHandlingType>Storage Environment Temperature</storageHandlingType><storageHandlingHigh unit="Degrees Celsius" value="8"/><storageHandlingLow unit="Degrees Celsius" value="2"/><storageHandlingSpecialConditionText xsi:nil="true"/></storageHandling></environmentalConditions><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>