<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>395044de-ca4d-42df-9770-c23994e981a7</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>5</publicVersionNumber><publicVersionDate>2025-07-14</publicVersionDate><devicePublishDate>2015-09-22</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>08809155853262</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>PIN SCREW</brandName><versionModelNumber>31750-40-18</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>687941818</dunsNumber><companyName>BK MEDITECH CO.,LTD.</companyName><deviceCount>1</deviceCount><deviceDescription>Cortical Pin Screw, 5mm Shaft Diameter x 5mm Thread Diameter x 180mm Total Length x 40mm Thread Length</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><premarketSubmissions><premarketSubmission><submissionNumber>K061599</submissionNumber><supplementNumber>000</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>32854</gmdnCode><gmdnPTName>Orthopaedic bone pin, non-bioabsorbable</gmdnPTName><gmdnPTDefinition>A thin, implantable rod intended to be used for the stabilization of a bone fracture or bone grafts, or for an osteotomy or arthrodesis (internal and/or external fixation). It is typically drilled into bone and may be smooth or threaded, solid or cannulated, and/or semi-flexible. Also known as a Kirschner-wire (K-wire), it may in addition be intended to assist with the introduction of a surgical instrument and/or implant; it is not intended for implantation into the intramedullary canal (i.e., not a nail). It is made of a non-bioabsorbable material (e.g., stainless steel). Some designs may have a break-off shank and/or be coated to improve long-term fixation. This is a single-use device.</gmdnPTDefinition><implantable>true</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>JDW</productCode><productCodeName>Pin, Fixation, Threaded</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>