<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>282dcf5c-99b6-44f8-8305-f44f0db20aa6</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>3</publicVersionNumber><publicVersionDate>2024-07-23</publicVersionDate><devicePublishDate>2018-10-01</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>08809317540559</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>FREND TSH Linearity Kit</brandName><versionModelNumber>FLK-TSH</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>687910463</dunsNumber><companyName>NanoEnTek, Inc.</companyName><deviceCount>1</deviceCount><deviceDescription>FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only.
FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
</deviceDescription><DMExempt>false</DMExempt><premarketExempt>true</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>true</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><gmdnTerms><gmdn><gmdnCode>55864</gmdnCode><gmdnPTName>Non-blood cell primer/calibrator/control material IVD, reagent</gmdnPTName><gmdnPTDefinition>A substance or reactant intended to be used as a non-blood cell primer, calibrator and/or control to prepare or establish the operational performance of an instrument prior to its use in routine haematological analysis of a clinical specimen.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>JJX</productCode><productCodeName>Single (Specified) Analyte Controls (Assayed And Unassayed)</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>