{"publicDeviceRecordKey":"6172546c-bb3e-461f-9ee0-08d5908c1b74","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":3,"publicVersionDate":"2026-04-08T00:00:00.000Z","devicePublishDate":"2021-10-15T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"08809744972763","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Esophageal TTS Stent","versionModelNumber":"EST1806F-22","catalogNumber":null,"dunsNumber":"689484322","companyName":"TAEWOONGMEDICAL.CO.,LTD","deviceCount":1,"deviceDescription":"Fully Covered Esophageal Stent System","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":false,"serialNumber":true,"manufacturingDate":true,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"MR Conditional","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"323-692-0028","phoneExtension":null,"email":"minsoo@taewoongusa.com"},{"phone":"+82319960641","phoneExtension":null,"email":"contact@stent.net"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K211706","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"61751","gmdnPTName":"Polymer-metal oesophageal stent","gmdnPTDefinition":"A non-bioabsorbable, expandable, tubular device intended to be implanted into the oesophagus to maintain luminal patency in strictures, prevent tumour in-growth, seal oesophageal fistulas, reduce acute bleeding from oesophageal varices, and/or to treat other lesions causing oesophageal leakage (e.g., anastomotic). It consists of a mesh structure made of metal which is covered/lined with a synthetic polymer material (e.g., silicone) that prevents lateral flow and tissue ingrowth and facilitates removability. It is typically expanded in situ (e.g., self-expands) and disposable devices intended to assist implantation may be included.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"ESW","productCodeName":"Prosthesis, Esophageal"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Stent Diameter","size":{"unit":"Millimeter","value":"18"},"sizeText":null,"sizeString":"Stent Diameter: 18 Millimeter"},{"sizeType":"Stent Length","size":{"unit":"Centimeter","value":"6"},"sizeText":null,"sizeString":"Stent Length: 6 Centimeter"},{"sizeType":"Catheter Working Length","size":{"unit":"Centimeter","value":"220"},"sizeText":null,"sizeString":"Catheter Working Length: 220 Centimeter"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":true,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}