<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>39273831-0ae7-43e5-9af1-675cdcba9165</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>5</publicVersionNumber><publicVersionDate>2024-03-18</publicVersionDate><devicePublishDate>2016-08-08</devicePublishDate><deviceCommDistributionEndDate>2023-12-04</deviceCommDistributionEndDate><deviceCommDistributionStatus>Not in Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>M272AU8D5L251</deviceId><deviceIdType>Secondary</deviceIdType><deviceIdIssuingAgency>HIBCC</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier><identifier><deviceId>10381780036531</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>Auragen™</brandName><versionModelNumber>AU8D5L25</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>531408342</dunsNumber><companyName>INTEGRA NEUROSCIENCES IMPLANT (FRANCE)</companyName><deviceCount>1</deviceCount><deviceDescription>The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>true</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>true</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>true</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>+1(800)654-2873</phone><phoneExtension xsi:nil="true"/><email>custsvcnj@integralife.com</email></customerContact></contacts><premarketSubmissions><premarketSubmission><submissionNumber>K926424</submissionNumber><supplementNumber>000</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>32556</gmdnCode><gmdnPTName>Depth electrode</gmdnPTName><gmdnPTDefinition>An electrical conductor intended to be temporarily placed (&lt; 30 days) beneath the surface of the brain to stimulate the brain or to record the brain&apos;s electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>GYC</productCode><productCodeName>ELECTRODE, CORTICAL</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>8 platinum contacts</sizeText></deviceSize></deviceSizes><environmentalConditions><storageHandling><storageHandlingType>Special Storage Condition, Specify</storageHandlingType><storageHandlingHigh unit="" value=""/><storageHandlingLow unit="" value=""/><storageHandlingSpecialConditionText>Room temperature</storageHandlingSpecialConditionText></storageHandling></environmentalConditions><sterilization><deviceSterile>true</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>