<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>5964283d-4249-4f33-bc94-44a5f5a22285</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>6</publicVersionNumber><publicVersionDate>2024-06-28</publicVersionDate><devicePublishDate>2015-10-14</devicePublishDate><deviceCommDistributionEndDate>2024-06-27</deviceCommDistributionEndDate><deviceCommDistributionStatus>Not in Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>10757770519085</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>EnVista MX60 IOL</brandName><versionModelNumber>MX60TP500+155</versionModelNumber><catalogNumber>MX60TP500+155</catalogNumber><dunsNumber>196603781</dunsNumber><companyName>Bausch &amp; Lomb Incorporated</companyName><deviceCount>1</deviceCount><deviceDescription>MX60TP500 12.5MM +15.5</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>false</lotBatch><serialNumber>true</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><gmdnTerms><gmdn><gmdnCode>35658</gmdnCode><gmdnPTName>Posterior-chamber intraocular lens, pseudophakic</gmdnPTName><gmdnPTDefinition>An optical device, generally referred to as an intraocular lens (IOL), intended to be implanted permanently in the posterior chamber of the eye (ring-like space filled with aqueous humor between the iris, the crystalline lens, and the ciliary body) to replace the natural lens (crystalline lens), typically because it has been clouded by a cataract. The device is made of a synthetic material (e.g., plastic, hydrogel). Included may be a sterile, single-use, IOL injector into which this device is preloaded and ready for insertion into the eye. Disposable devices associated with implantation (e.g., IOL injector) may be included with the lens.</gmdnPTDefinition><implantable>true</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>HQL</productCode><productCodeName>Intraocular Lens</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions/><sterilization><deviceSterile>true</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>