{"publicDeviceRecordKey":"716a4278-92c6-4228-a539-f55da62308a6","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":6,"publicVersionDate":"2023-01-10T00:00:00.000Z","devicePublishDate":"2016-08-22T00:00:00.000Z","deviceCommDistributionEndDate":"2023-01-10T00:00:00.000Z","deviceCommDistributionStatus":"Not in Commercial Distribution","identifiers":{"identifier":[{"deviceId":"10873263001162","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null},{"deviceId":"00873263001165","deviceIdType":"Unit of Use","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"microTargeting™ Electrode and Insertion Tube Kit","versionModelNumber":"FC4001-00116","catalogNumber":"FC4001","dunsNumber":"108179458","companyName":"FHC, INC.","deviceCount":5,"deviceDescription":"microTargeting D.ZAP Electrode Kit, 5x, Sterile, Single, 1 Meg, for use with NexFrame and NexDrive or mT Drive.\nEach box contains: \n2x MTDPLN(PA)(DB2) D.ZAP Differential Electrode.\n1x IT(DB3) Insertion tube with Stylet.\n1x PT(DB5) Protective Tube.\nIndividual Specifications:\nMTDPLN(PA)(DB2) - 249.2mm electrode length, 10mm tip exposure, 234.2mm protective tube length, .56mm od, 1.0 meg DZAP(L)\nIT(DB3) - 194mm length, 1.8mm od, 1.6mm id, \nPT(DB5) - 194mm length, 1.47mm od, 0.99mm id","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"MR Unsafe","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(800)326-2905","phoneExtension":null,"email":"fhcinc@fh-co.com"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K011775","supplementNumber":"000"},{"submissionNumber":"K033173","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"32556","gmdnPTName":"Depth electrode","gmdnPTDefinition":"An electrical conductor intended to be temporarily placed (\u003c 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device.","implantable":false,"gmdnCodeStatus":"Active"},{"gmdnCode":"61964","gmdnPTName":"Intracerebral cannula, implantable","gmdnPTDefinition":"A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"HAW","productCodeName":"Neurological stereotaxic Instrument"},{"productCode":"GZL","productCodeName":"ELECTRODE, DEPTH"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[{"storageHandlingType":"Handling Environment Humidity","storageHandlingHigh":{"unit":"Percent (%) Relative Humidity","value":"95"},"storageHandlingLow":{"unit":"Percent (%) Relative Humidity","value":"0"},"storageHandlingSpecialConditionText":null},{"storageHandlingType":"Storage Environment Temperature","storageHandlingHigh":{"unit":"Degrees Celsius","value":"40"},"storageHandlingLow":{"unit":"Degrees Celsius","value":"0"},"storageHandlingSpecialConditionText":null},{"storageHandlingType":"Storage Environment Humidity","storageHandlingHigh":{"unit":"Percent (%) Relative Humidity","value":"95"},"storageHandlingLow":{"unit":"Percent (%) Relative Humidity","value":"0"},"storageHandlingSpecialConditionText":null}]},"sterilization":{"deviceSterile":true,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Ethylene Oxide","Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}