{"publicDeviceRecordKey":"fffe3034-a181-4b34-ba65-b44c1a47fc94","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":4,"publicVersionDate":"2019-09-23T00:00:00.000Z","devicePublishDate":"2016-10-13T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"10873263005344","deviceIdType":"Primary","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null},{"deviceId":"00873263005347","deviceIdType":"Unit of Use","deviceIdIssuingAgency":"GS1","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"microTargeting™ Electrode","versionModelNumber":"MTDWLN(BS)(FM2)-00534","catalogNumber":"MTDWLN(BS)(FM2)","dunsNumber":"108179458","companyName":"FHC, INC.","deviceCount":6,"deviceDescription":"microTargeting(TM) Electrode, differential, tungsten, D.ZAP(L), nonsterile","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"MR Unsafe","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(800)326-2905","phoneExtension":null,"email":"fhcinc@fh-co.com"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K033173","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"32556","gmdnPTName":"Depth electrode","gmdnPTDefinition":"An electrical conductor intended to be temporarily placed (\u003c 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"GZL","productCodeName":"ELECTRODE, DEPTH"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Outer Diameter","size":{"unit":"Millimeter","value":"0.77"},"sizeText":null,"sizeString":"Outer Diameter: 0.77 Millimeter"},{"sizeType":"Length","size":{"unit":"Millimeter","value":"2"},"sizeText":null,"sizeString":"Length: 2 Millimeter"},{"sizeType":"Length","size":{"unit":"Millimeter","value":"93"},"sizeText":null,"sizeString":"Length: 93 Millimeter"},{"sizeType":"Length","size":{"unit":"Millimeter","value":"100"},"sizeText":null,"sizeString":"Length: 100 Millimeter"},{"sizeType":"Device Size Text, specify","size":{"unit":"","value":""},"sizeText":"Impedance: Megaohms"}]},"environmentalConditions":{"storageHandling":[{"storageHandlingType":"Storage Environment Temperature","storageHandlingHigh":{"unit":"Degrees Celsius","value":"40"},"storageHandlingLow":{"unit":"Degrees Celsius","value":"0"},"storageHandlingSpecialConditionText":null},{"storageHandlingType":"Storage Environment Humidity","storageHandlingHigh":{"unit":"Percent (%) Relative Humidity","value":"95"},"storageHandlingLow":{"unit":"Percent (%) Relative Humidity","value":"0"},"storageHandlingSpecialConditionText":null},{"storageHandlingType":"Handling Environment Humidity","storageHandlingHigh":{"unit":"Percent (%) Relative Humidity","value":"95"},"storageHandlingLow":{"unit":"Percent (%) Relative Humidity","value":"0"},"storageHandlingSpecialConditionText":null}]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization","Ethylene Oxide"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}