<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>989b3923-f2e4-42f2-803f-1c9b15fbbfed</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>6</publicVersionNumber><publicVersionDate>2024-04-03</publicVersionDate><devicePublishDate>2014-09-20</devicePublishDate><deviceCommDistributionEndDate>2021-12-31</deviceCommDistributionEndDate><deviceCommDistributionStatus>Not in Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>10886704043614</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>CODMAN</brandName><versionModelNumber>AP-03000M</versionModelNumber><catalogNumber>AP03000M</catalogNumber><dunsNumber>607846297</dunsNumber><companyName>Cerenovus, Inc.</companyName><deviceCount>1</deviceCount><deviceDescription>Constant Flow Implantable Pump With Bolus Safety Valve and Operating Room Prep Kit</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>false</lotBatch><serialNumber>true</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>+1(800)255-2500</phone><phoneExtension xsi:nil="true"/><email>xx@xx.xx</email></customerContact></contacts><premarketSubmissions><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>001</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>002</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>003</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>006</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>010</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>011</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>013</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>014</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>015</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>017</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>019</supplementNumber></premarketSubmission><premarketSubmission><submissionNumber>P890055</submissionNumber><supplementNumber>052</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>34071</gmdnCode><gmdnPTName>Implantable intrathecal infusion pump, nonprogrammable</gmdnPTName><gmdnPTDefinition>A battery-powered nonprogrammable device designed to be implanted in a patient for the storing and subarachnoid administration of narcotics/drugs (e.g., morphine sulfate, baclofen) to manage intractable pain and muscle spasms of malignant or non-malignant origin. This implantable infusion pump (IIP) may enable delivery of a bolus of medication, typically patient-controlled with mechanical restrictions that limit the refill rate of the device, or it may provide a constant flow of medication at a factory-set rate. The device typically consists of a refillable drug reservoir, usually implanted under the skin of the lower abdomen, and a connected catheter placed into the spinal fluid space.</gmdnPTDefinition><implantable>true</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>LKK</productCode><productCodeName>PUMP, INFUSION, IMPLANTED, PROGRAMMABLE</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions><storageHandling><storageHandlingType>Special Storage Condition, Specify</storageHandlingType><storageHandlingHigh unit="" value=""/><storageHandlingLow unit="" value=""/><storageHandlingSpecialConditionText>Do not use if opened or damaged.</storageHandlingSpecialConditionText></storageHandling><storageHandling><storageHandlingType>Special Storage Condition, Specify</storageHandlingType><storageHandlingHigh unit="" value=""/><storageHandlingLow unit="" value=""/><storageHandlingSpecialConditionText>Do not drop</storageHandlingSpecialConditionText></storageHandling><storageHandling><storageHandlingType>Special Storage Condition, Specify</storageHandlingType><storageHandlingHigh unit="" value=""/><storageHandlingLow unit="" value=""/><storageHandlingSpecialConditionText>Protect package from water</storageHandlingSpecialConditionText></storageHandling></environmentalConditions><sterilization><deviceSterile>true</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>