<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>d79a2564-98b7-4e16-9081-2debf19be8c1</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>5</publicVersionNumber><publicVersionDate>2025-01-16</publicVersionDate><devicePublishDate>2016-10-12</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>14026704533784</deviceId><deviceIdType>Direct Marking</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier><identifier><deviceId>34026704533788</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier><identifier><deviceId>24026704533781</deviceId><deviceIdType>Previous</deviceIdType><deviceIdIssuingAgency>GS1</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>PILLING</brandName><versionModelNumber>IPN008225</versionModelNumber><catalogNumber>511745</catalogNumber><dunsNumber>002348191</dunsNumber><companyName>TELEFLEX INCORPORATED</companyName><deviceCount>1</deviceCount><deviceDescription>TUCKER TRACHEA TUBE #8</deviceDescription><DMExempt>false</DMExempt><premarketExempt>true</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>true</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>MR Unsafe</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>+1(919)544-8000</phone><phoneExtension xsi:nil="true"/><email>CS@TELEFLEX.COM</email></customerContact></contacts><gmdnTerms><gmdn><gmdnCode>38792</gmdnCode><gmdnPTName>Tracheostomy tube, non-reinforced, non-customized, reusable</gmdnPTName><gmdnPTDefinition>A hollow cylinder designed to be inserted into an artificial opening made in the trachea (windpipe) during a tracheotomy to provide a patent airway; it is not custom-made for a specific patient and is not reinforced with a wire. It is typically constructed of metal [stainless steel, silver (Ag) and/or silver plated brass] or plastic and may include an inner cannula. It is available in cuffed, uncuffed, and/or fenestrated versions, and in a variety of shapes and sizes. It is secured in position by a tracheostomy tube holder fastened around the patient&apos;s neck. This is a reusable device.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>BTO</productCode><productCodeName>Tube, tracheostomy (w/wo connector)</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Length</sizeType><size unit="Millimeter" value="61"/><sizeText xsi:nil="true"/></deviceSize></deviceSizes><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>