{"publicDeviceRecordKey":"5b4b4516-63c4-4ab0-b809-de79bc2b07da","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":4,"publicVersionDate":"2020-02-24T00:00:00.000Z","devicePublishDate":"2017-01-13T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"B030CP009690","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"ORTHROS","versionModelNumber":"CP-009-69","catalogNumber":null,"dunsNumber":"054205979","companyName":"CAMBER SPINE TECHNOLOGIES, LLC","deviceCount":1,"deviceDescription":"Ø5.5mm Anti-Rotation Curved Rod , 130 mm Lg.","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":true,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"1-866-643-0739","phoneExtension":null,"email":"customerservice@cambermedtech.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"60762","gmdnPTName":"Polymeric spinal interbody fusion cage","gmdnPTDefinition":"A device intended to be implanted into the space of an intervertebral disc that has been partially or totally removed during surgery in order to allow bone fusion between two contiguous vertebral bodies, typically in the treatment of degenerative disc disease (DDD). It is in the form of a hollow, porous, threaded and/or fenestrated cylindrical or geometrical device made of non-bioabsorbable synthetic polymer [e.g., polyetheretherketone (PEEK)] that provides mechanical stability and sufficient space for therapeutic spinal bone fusion to occur; bone graft is typically used to help with osseointegration. Fixation screws and devices associated with implantation may be included with the device.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"NKB","productCodeName":"Thoracolumbosacral Pedicle Screw System"},{"productCode":"KWQ","productCodeName":"Appliance, Fixation, Spinal Intervertebral Body"},{"productCode":"MNH","productCodeName":"Orthosis, Spondylolisthesis Spinal Fixation"},{"productCode":"MNI","productCodeName":"Orthosis, Spinal Pedicle Fixation"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Length","size":{"unit":"Millimeter","value":"130"},"sizeText":null,"sizeString":"Length: 130 Millimeter"},{"sizeType":"Outer Diameter","size":{"unit":"Millimeter","value":"5.5"},"sizeText":null,"sizeString":"Outer Diameter: 5.5 Millimeter"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}