<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>0328c814-a2ca-4bcc-9e21-d5ef8e451dc8</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>5</publicVersionNumber><publicVersionDate>2022-12-20</publicVersionDate><devicePublishDate>2016-07-05</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>B07601650</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>HIBCC</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>Ecstasy DAU Calibrator, High Calibrator</brandName><versionModelNumber>0165</versionModelNumber><catalogNumber>0165</catalogNumber><dunsNumber>840839190</dunsNumber><companyName>LIN-ZHI INTERNATIONAL, INC.</companyName><deviceCount>1</deviceCount><deviceDescription>5mL/bottle.
Concentration: 1000 ng/mL of MDMA.</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>true</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts/><premarketSubmissions><premarketSubmission><submissionNumber>K033094</submissionNumber><supplementNumber>000</supplementNumber></premarketSubmission></premarketSubmissions><gmdnTerms><gmdn><gmdnCode>55490</gmdnCode><gmdnPTName>Amphetamine/methamphetamine group IVD, calibrator</gmdnPTName><gmdnPTDefinition>A material which is used to establish known points of reference for an assay intended to be used for the qualitative and/or quantitative detection of multiple drugs belonging to the amphetamine and/or methamphetamine group(s) in a clinical specimen.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>DLJ</productCode><productCodeName>Calibrators, Drug Specific</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions><storageHandling><storageHandlingType>Storage Environment Temperature</storageHandlingType><storageHandlingHigh unit="Degrees Celsius" value="8"/><storageHandlingLow unit="Degrees Celsius" value="2"/><storageHandlingSpecialConditionText xsi:nil="true"/></storageHandling></environmentalConditions><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>