{"publicDeviceRecordKey":"e8d906db-1743-466f-8eaf-73ddb9a01f97","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":2,"publicVersionDate":"2023-05-03T00:00:00.000Z","devicePublishDate":"2021-08-28T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"B1132R2GR000000","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Shoulder Innovations Inset Reverse Total Shoulder","versionModelNumber":"RSA Glenoid Reamer Wrench","catalogNumber":"2R2GR00000","dunsNumber":"080404519","companyName":"Shoulder Innovations, Inc.","deviceCount":1,"deviceDescription":"Shoulder Innovations Inset Reverse Total Shoulder - RSA Glenoid Reamer Wrench","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"616.294.1026","phoneExtension":null,"email":"info@shoulderinnovations.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"35670","gmdnPTName":"Total shoulder prosthesis","gmdnPTDefinition":"A sterile implantable artificial substitute for a shoulder joint designed to replace both articulating surfaces of the damaged (e.g., fractured) and/or degenerative (e.g., arthritic) joint. It includes glenoid and humeral (head and stem) components typically with parts made of metal and polyethylene (PE). Fixation devices for implantation (e.g., screws) may be included and implantation may be performed with or without bone cement.","implantable":true,"gmdnCodeStatus":"Active"},{"gmdnCode":"33711","gmdnPTName":"Total reverse shoulder prosthesis","gmdnPTDefinition":"A sterile implantable artificial substitute for a shoulder joint designed to replace both articulating surfaces of the joint particularly in patients with chronic, longstanding rotator cuff muscle tears, arthritis, and/or humeral fractures unsuccessfully treated by previous surgery. The device reverses normal anatomy so that the head portion of the joint is attached to the scapula and the socket portion is attached to the humerus. It typically includes a humeral stem and glenosphere (head) with body and cup components. The device may include screws for implantation and may be implanted with or without bone cement.","implantable":true,"gmdnCodeStatus":"Active"},{"gmdnCode":"13180","gmdnPTName":"Orthopaedic prosthesis implantation positioning instrument, reusable","gmdnPTDefinition":"A hand-held surgical instrument intended to be used during implantation of an orthopaedic prosthesis, either manually or as a computer-assisted surgery (CAS) device, to aid in the navigation/placement of the prosthesis or other instruments [e.g., drill sleeves and guide wires (Kirschner wires), patella saw guide]. It may be used for the following applications: 1) to hold/align/fix/guide other instruments, prostheses, or prosthesis components; 2) to provide relative position landmarks; 3) to ascertain correct spatial orientation or limb alignment; and/or 4) as an interface (non-adaptive) between prosthesis components. This is a reusable device intended to be sterilized prior to use.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"MBF","productCodeName":"Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented"},{"productCode":"PHX","productCodeName":"Shoulder Prosthesis, Reverse Configuration"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}