{"publicDeviceRecordKey":"7576b80b-3189-4d76-9a13-31a22263b7d3","publicVersionStatus":"New","deviceRecordStatus":"Published","publicVersionNumber":1,"publicVersionDate":"2019-09-11T00:00:00.000Z","devicePublishDate":"2019-09-03T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"B144MPC7801","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null},{"deviceId":"B144MPC7800","deviceIdType":"Unit of Use","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Molded Products, Inc.","versionModelNumber":"MPC-780","catalogNumber":"MPC-780","dunsNumber":"157506015","companyName":"MOLDED PRODUCTS, INC.","deviceCount":10,"deviceDescription":"Hansen Male Connector with 3/8-18 NPT Male","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":false,"otc":false,"contacts":{"customerContact":[]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K022068","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"58130","gmdnPTName":"Haemodialysis system, institutional","gmdnPTDefinition":"An assembly of mains electricity (AC-powered) devices intended to be used to perform patient haemodialysis, a treatment whereby extracorporeal blood is passed through a filter to allow for the removal of toxins and/or the replacement of electrolytes, by trained professionals in a healthcare facility. The system functions with dialysate solution and a haemodialysis dialyser (haemodialyzer) for the transfer of substances by diffusion, osmosis and ultrafiltration. It typically includes a pump and tubing to circulate blood through the haemodialysis dialyser, a solution mixer to prepare the dialysate, a monitor with system controls, and other dedicated components.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"FID","productCodeName":"Tubing, Dialysate"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":false,"methodTypes":{"sterilizationMethod":[]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}