{"publicDeviceRecordKey":"f3c81cf4-2d3e-43c5-a9ca-edec9720dcf5","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":3,"publicVersionDate":"2024-01-01T00:00:00.000Z","devicePublishDate":"2023-07-08T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"B35410","deviceIdType":"Unit of Use","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null},{"deviceId":"B354OSAPG1","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"Alligator Padded Grasper","versionModelNumber":"OSAPG","catalogNumber":null,"dunsNumber":"047063695","companyName":"ORANGE SURGICAL INSTRUMENTS, LLC","deviceCount":5,"deviceDescription":"Alligator Padded Grasper\n","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":false,"serialNumber":true,"manufacturingDate":false,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K101733","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"33596","gmdnPTName":"Endoscopic electrosurgical handpiece/electrode, monopolar, reusable","gmdnPTDefinition":"An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and requires a patient contact return electrode to complete the circuit. This is a reusable device.","implantable":false,"gmdnCodeStatus":"Active"},{"gmdnCode":"61875","gmdnPTName":"Endoscopic electrosurgical electrode, monopolar, single-use","gmdnPTDefinition":"A sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It is available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece or housing and has no electrical or mechanical controls (e.g., does not include ring-handles); it is not intended for gas-enhanced electrosurgery. This is a single-use device.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"GEI","productCodeName":"Electrosurgical, Cutting \u0026 Coagulation \u0026 Accessories"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Peracetic Acid"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}