{"publicDeviceRecordKey":"d10ffb28-af76-484a-b9be-f8cc9d541145","publicVersionStatus":"New","deviceRecordStatus":"Published","publicVersionNumber":1,"publicVersionDate":"2023-07-28T00:00:00.000Z","devicePublishDate":"2023-07-20T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"B458201058000","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"STANDARD CANNULA SET","versionModelNumber":"20105800","catalogNumber":"20-1058-00","dunsNumber":"048931625","companyName":"The Wells Johnson Company","deviceCount":1,"deviceDescription":"Cannula Set, Standard Cannula Set, contains:\n-3-Port Radial (Mercedes) 3mm x 25cm on 7/8\" tip base w/vent (P/N: 20-1205-00)\n-3-Port Radial (Mercedes) 3mm x 15cm on 7/8\" tip base w/vent (P/N: 20-1205-00)\n-Triport (Accelerator) 4mm x 25cm on 7/8\" tip base w/vent (P/N: 20-1207-00)\n-Triport (Accelerator) 3mm x 25cm on 7/8\" tip base w/vent (P/N: 20-1207-00)\n-Becker Grater Round 3mm x 25cm on 7/8\" tip base (P/N: 20-1230-00)\n-Puente Tornado 2.7mm x 17cm on 7/8\" tip base w/vent (P/N: 20-1236-00)\n-Puente Tornado 2mm x 15cm on 7/8\" tip base w/vent (P/N: 20-1236-00)\n-1\" Delrin Handle x2ea (P/N: 20-0005-00)","DMExempt":false,"premarketExempt":true,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":false,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[]},"gmdnTerms":{"gmdn":[{"gmdnCode":"45414","gmdnPTName":"Liposuction system cannula, reusable","gmdnPTDefinition":"A rigid tube that functions as a component of a lipectomy suction system and designed specifically for percutaneous insertion into body fat deposits for the aspiration of fat during liposuction/lipoplasty. The device may also be used to infiltrate the operative site with a solution during the procedure, which is then aspirated. This is a reusable device.","implantable":false,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"GEA","productCodeName":"Cannula, Surgical, General \u0026 Plastic Surgery"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}