{"publicDeviceRecordKey":"383c34c2-3457-46ba-8add-c0e756435b89","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":4,"publicVersionDate":"2021-02-19T00:00:00.000Z","devicePublishDate":"2015-10-30T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"EBES04181R0","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"TRACHEOBRONXANE™ DUMON™ RADIO OPAQUE","versionModelNumber":"04181R","catalogNumber":"04181R","dunsNumber":"777211640","companyName":"NOVATECH","deviceCount":1,"deviceDescription":"TD 18 L 80","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":true,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+33442981560","phoneExtension":null,"email":"info@novatech.fr"}]},"premarketSubmissions":{"premarketSubmission":[{"submissionNumber":"K971509","supplementNumber":"000"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"46977","gmdnPTName":"Polymeric tracheal/bronchial stent, non-bioabsorbable","gmdnPTDefinition":"A non-bioabsorbable tubular device intended to be implanted into the trachea and/or a bronchus/bronchiole to maintain luminal patency, typically used in cases of obstructions/stenoses, fistulae, tumours, scarring, surgical resection and anastomosis, or pulmonary transplantation. It is made entirely of a synthetic polymer(s) [e.g., silicone] and may have various designs (e.g., semi-soft continuous tube, covered or non-covered mesh structure, straight or branched configuration) intended to conform to the endotracheal/endobronchial surface. It may be expandable in situ (e.g., self-expands) and disposable devices intended to assist implantation may be included.","implantable":true,"gmdnCodeStatus":"Active"}]},"productCodes":{"fdaProductCode":[{"productCode":"NWA","productCodeName":"Prosthesis, Tracheal, Preformed/Molded"}]},"deviceSizes":{"deviceSize":[]},"environmentalConditions":{"storageHandling":[{"storageHandlingType":"Special Storage Condition, Specify","storageHandlingHigh":{"unit":"","value":""},"storageHandlingLow":{"unit":"","value":""},"storageHandlingSpecialConditionText":"Keep away from sunlight"},{"storageHandlingType":"Special Storage Condition, Specify","storageHandlingHigh":{"unit":"","value":""},"storageHandlingLow":{"unit":"","value":""},"storageHandlingSpecialConditionText":"Keep dry"}]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null}