<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>670a24bd-1fda-4ede-a209-e5912e56b55b</publicDeviceRecordKey><publicVersionStatus>New</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>1</publicVersionNumber><publicVersionDate>2025-06-09</publicVersionDate><devicePublishDate>2025-05-30</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>G412PH2002S0</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>HIBCC</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>MR PHACO</brandName><versionModelNumber>PH2002S</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>836285668</dunsNumber><companyName>Crestpoint Management Limited</companyName><deviceCount>1</deviceCount><deviceDescription>Chang Nucleus Hydrodissection Cannula 27ga, 1.25mm flat Standard tip angled 90° with beveled opening, 16mm Overall Length</deviceDescription><DMExempt>false</DMExempt><premarketExempt>true</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>true</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>false</rx><otc>false</otc><contacts/><gmdnTerms><gmdn><gmdnCode>17899</gmdnCode><gmdnPTName>Ophthalmic irrigation/infusion/aspiration cannula, non-illuminating, reusable</gmdnPTName><gmdnPTDefinition>A rigid or semi-rigid tube (non-illuminating) designed to be inserted into the eye to facilitate infusion, irrigation, and/or aspiration of fluids/gases during ophthalmic surgery (e.g., phacoemulsification, vitreoretinal surgery, sub-Tenon’s anaesthesia, capsule polishing). It is a single- or multi-lumen device, typically made of high-grade stainless steel, and may include a length of flexible tubing. It may be blunt, or include a sharp angled tip/hook (e.g., irrigating cystotome for capsulotomy), however it does not have a sharp bevelled end for initial puncture of the eye (i.e., not a needle). This is a reusable device intended to be sterilized prior to use.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>HMX</productCode><productCodeName>Cannula, Ophthalmic</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>