<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>2afa7c26-a11e-4118-ae7b-ba664c1c005c</publicDeviceRecordKey><publicVersionStatus>New</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>1</publicVersionNumber><publicVersionDate>2025-06-10</publicVersionDate><devicePublishDate>2025-06-02</devicePublishDate><deviceCommDistributionEndDate xsi:nil="true"/><deviceCommDistributionStatus>In Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>G412PH93040</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>HIBCC</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>MR PHACO</brandName><versionModelNumber>PH9304</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>836285668</dunsNumber><companyName>Crestpoint Management Limited</companyName><deviceCount>1</deviceCount><deviceDescription>Osher Capsulorhexis Ring Marker 5.75 Inner diameter, 6.44mm Outer diameter
</deviceDescription><DMExempt>false</DMExempt><premarketExempt>true</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>false</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>true</manufacturingDate><expirationDate>false</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>false</rx><otc>false</otc><contacts/><gmdnTerms><gmdn><gmdnCode>37896</gmdnCode><gmdnPTName>Corneal marker, reusable</gmdnPTName><gmdnPTDefinition>A manual instrument intended to be used to imprint, indent, and/or incise corneal tissue prior to an ophthalmic surgical procedure. It is typically made of high-grade stainless steel and includes a long slender handle with a distal end having characteristics for producing specific markings. The device may have a defined pattern of fine marking surfaces (e.g., cross hairs, symmetrical or asymmetrical interlinking wires) that simultaneously engage corneal tissue. Some types are used with a corneal marking pad to transfer ink to the anterior of the eye; other types are used with a slit lamp to precisely incise vertical and horizontal points for precision alignment. This is a reusable device.</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>HMR</productCode><productCodeName>Marker, Ocular</productCodeName></fdaProductCode></productCodes><deviceSizes/><environmentalConditions/><sterilization><deviceSterile>false</deviceSterile><sterilizationPriorToUse>true</sterilizationPriorToUse><methodTypes><sterilizationMethod>Moist Heat or Steam Sterilization</sterilizationMethod></methodTypes></sterilization></device>