<?xml version='1.0' encoding='UTF-8'?><device xmlns='http://www.fda.gov/cdrh/gudid' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'><publicDeviceRecordKey>c69d76a0-9e30-4ab7-8b29-f3a9fd75f1bf</publicDeviceRecordKey><publicVersionStatus>Update</publicVersionStatus><deviceRecordStatus>Published</deviceRecordStatus><publicVersionNumber>6</publicVersionNumber><publicVersionDate>2023-06-09</publicVersionDate><devicePublishDate>2016-09-05</devicePublishDate><deviceCommDistributionEndDate>2021-08-30</deviceCommDistributionEndDate><deviceCommDistributionStatus>Not in Commercial Distribution</deviceCommDistributionStatus><identifiers><identifier><deviceId>M20684010</deviceId><deviceIdType>Primary</deviceIdType><deviceIdIssuingAgency>HIBCC</deviceIdIssuingAgency><containsDINumber xsi:nil="true"/><pkgQuantity xsi:nil="true"/><pkgDiscontinueDate xsi:nil="true"/><pkgStatus xsi:nil="true"/><pkgType xsi:nil="true"/></identifier></identifiers><brandName>Expro Elite™ snare</brandName><versionModelNumber>8401</versionModelNumber><catalogNumber xsi:nil="true"/><dunsNumber>008999906</dunsNumber><companyName>Vascular Solutions, Inc.</companyName><deviceCount>1</deviceCount><deviceDescription>The EXPRO Elite Snares are intended for use in the cardiovascular system and hollow viscus to retrieve and/or manipulate objects using minimally invasive surgical procedures. Manipulation procedures include retrieval and/or repositioning of intravascular foreign objects such as coils, balloons, catheters and/or guidewires within the cardiovascular system.</deviceDescription><DMExempt>false</DMExempt><premarketExempt>false</premarketExempt><deviceHCTP>false</deviceHCTP><deviceKit>false</deviceKit><deviceCombinationProduct>false</deviceCombinationProduct><singleUse>true</singleUse><lotBatch>true</lotBatch><serialNumber>false</serialNumber><manufacturingDate>false</manufacturingDate><expirationDate>true</expirationDate><donationIdNumber>false</donationIdNumber><labeledContainsNRL>false</labeledContainsNRL><labeledNoNRL>false</labeledNoNRL><MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus><rx>true</rx><otc>false</otc><contacts><customerContact><phone>888-240-6001</phone><phoneExtension xsi:nil="true"/><email>customerservice@vasc.com</email></customerContact></contacts><gmdnTerms><gmdn><gmdnCode>17927</gmdnCode><gmdnPTName>Intravascular extraction catheter-snare</gmdnPTName><gmdnPTDefinition>A flexible, end- and/or side-hole tube with a long snaring device (e.g., a wire loop or noose) inserted through its lumen, designed to be introduced into a blood vessel or similar structure to manually retrieve or manipulate a foreign body. It is typically available in two forms: 1) the loop emerges from the distal tip of the catheter while both free ends of the wire emerge from the proximal end; and 2) the end of the wire is attached to the distal end of the catheter while the free end is passed through the lumen to emerge at the proximal end. The wire is usually made of a high-strength, stiff metal [e.g., nickel-titanium alloy (Nitinol)].</gmdnPTDefinition><implantable>false</implantable><gmdnCodeStatus>Active</gmdnCodeStatus></gmdn></gmdnTerms><productCodes><fdaProductCode><productCode>MMX</productCode><productCodeName>Device, Percutaneous Retrieval</productCodeName></fdaProductCode></productCodes><deviceSizes><deviceSize><sizeType>Device Size Text, specify</sizeType><size unit="" value=""/><sizeText>10 mm Snare Loop</sizeText></deviceSize><deviceSize><sizeType>Length</sizeType><size unit="Centimeter" value="150"/><sizeText xsi:nil="true"/></deviceSize><deviceSize><sizeType>Outer Diameter</sizeType><size unit="Inch" value="0.035"/><sizeText xsi:nil="true"/></deviceSize></deviceSizes><environmentalConditions/><sterilization><deviceSterile>true</deviceSterile><sterilizationPriorToUse>false</sterilizationPriorToUse><methodTypes/></sterilization></device>