{"publicDeviceRecordKey":"569c08b3-0fb6-405c-899e-cf70374ee4fc","publicVersionStatus":"Update","deviceRecordStatus":"Published","publicVersionNumber":5,"publicVersionDate":"2025-07-02T00:00:00.000Z","devicePublishDate":"2016-01-21T00:00:00.000Z","deviceCommDistributionEndDate":null,"deviceCommDistributionStatus":"In Commercial Distribution","identifiers":{"identifier":[{"deviceId":"M7252014014","deviceIdType":"Primary","deviceIdIssuingAgency":"HIBCC","containsDINumber":null,"pkgQuantity":null,"pkgDiscontinueDate":null,"pkgStatus":null,"pkgType":null}]},"brandName":"ANODYNE Plate System","versionModelNumber":"20140-14","catalogNumber":"20140-14","dunsNumber":"064191453","companyName":"CORELINK LLC","deviceCount":1,"deviceDescription":"ANODYNE CERVICAL SCREW  - VARIABLE SELF DRILLING - 4.0MM X 14MM","DMExempt":false,"premarketExempt":false,"deviceHCTP":false,"deviceKit":false,"deviceCombinationProduct":false,"singleUse":true,"lotBatch":true,"serialNumber":false,"manufacturingDate":false,"expirationDate":false,"donationIdNumber":false,"labeledContainsNRL":false,"labeledNoNRL":false,"MRISafetyStatus":"Labeling does not contain MRI Safety Information","rx":true,"otc":false,"contacts":{"customerContact":[{"phone":"+1(314)863-5401","phoneExtension":null,"email":"customer.service@corelinksurgical.com"}]},"gmdnTerms":{"gmdn":[{"gmdnCode":"61325","gmdnPTName":"Bone-screw internal spinal fixation system, non-sterile","gmdnPTDefinition":"An assembly of non-sterile implantable devices intended to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities, also used as an adjunct to spinal fusion [e.g., for degenerative disc disease (DDD)]. Otherwise known as a pedicle screw instrumentation system, it typically consists of a combination of anchors (e.g., bolts, hooks, pedicle screws or other types), interconnection mechanisms (incorporating nuts, screws, sleeves, or bolts), longitudinal members (e.g., plates, rods, plate/rod combinations), and/or transverse connectors. Non-sterile disposable devices associated with implantation may be included.","implantable":false,"gmdnCodeStatus":"Obsolete"}]},"productCodes":{"fdaProductCode":[{"productCode":"KWQ","productCodeName":"APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY"}]},"deviceSizes":{"deviceSize":[{"sizeType":"Length","size":{"unit":"Millimeter","value":"14"},"sizeText":null,"sizeString":"Length: 14 Millimeter"},{"sizeType":"Outer Diameter","size":{"unit":"Millimeter","value":"4"},"sizeText":null,"sizeString":"Outer Diameter: 4 Millimeter"}]},"environmentalConditions":{"storageHandling":[]},"sterilization":{"deviceSterile":false,"sterilizationPriorToUse":true,"methodTypes":{"sterilizationMethod":["Moist Heat or Steam Sterilization"]}},"xmlns":"http://www.fda.gov/cdrh/gudid","xsi":"http://www.w3.org/2001/XMLSchema-instance","anomaly":null,"premarketSubmissions":{"premarketSubmission":[]}}