Array Insertion Electrode/Tube with Stylet Kit, 5x, Sterile, for use with Nexframe and microTargeting Drive. Contains: IT(AR8): Insertion Tube w/ Stylet. MTDPBN(PA)(DB2): microTargeting Electrode. Individual Specifications: IT(AR8) - 217mm tube length, 0.89mm OD, 0.58mm ID MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm differential length, 234.2mm protective tube length. 1 Meg RZAP, 0.56mm od
FHC, INC.
FC7100-00756
In Commercial Distribution

  • 10873263007560 ()
  • 00873263007563 ()
FC7100

  • Depth electrode
  • Intracerebral cannula, nonimplantable, single-use
microTargeting D.ZAP Electrode Kit, 5x, Sterile, Single, 1 Meg, for use with NexFrame and NexDrive or mT Drive. Each box contains: 2x MTDPLN(PA)(DB2) D.ZAP Differential Electrode. 1x IT(DB3) Insertion tube with Stylet. 1x PT(DB5) Protective Tube. Individual Specifications: MTDPLN(PA)(DB2) - 249.2mm electrode length, 10mm tip exposure, 234.2mm protective tube length, .56mm od, 1.0 meg DZAP(L) IT(DB3) - 194mm length, 1.8mm od, 1.6mm id, PT(DB5) - 194mm length, 1.47mm od, 0.99mm id
FHC, INC.
FC4001-00754
In Commercial Distribution

  • 10873263007546 ()
  • 00873263007549 ()
FC4001

  • Depth electrode
  • Intracerebral cannula, nonimplantable, single-use
microTargeting Frame Kit D.ZAP/Lead Insertion, 1x, Sterile, for use with mT Drive or STar Drive. Contains: 34685L: Single D.ZAP Electrode. 66-DA-SD: Drape Sleeve. 66-EL-LP: Patient Lead for LP+. 66-IT-05P: Single Insertion Tube Set.
FHC, INC.
KT-FPK-S20-00508
In Commercial Distribution

  • 00873263005088 ()
KT-FPK-S20

  • Depth electrode
  • Neurological stereotactic surgery system
  • Intracerebral cannula, implantable
microTargeting single electrode insertion tubes and electrodes kit, 5x, Sterile for use with NexFrame and NexDrive or mT Drive. Each Box Contains: 2x MTDPBN(PA)(DB2) Electrode. 1x IT(DB3) Insertion Tube with Stylet. 1x PT(DB5) Spacer Tube. Individual Specifications: MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm tip expsure, 234.3mm protective tube length, 0.56mm od, 1.0 meg. RZAP IT(DB3) - 194mm length, 1.8mm od, 1.6mm id. PT(DB5) - 194mm length, 1.47mm od, 0.99mm id.
FHC, INC.
FC4000-00115
Not in Commercial Distribution

  • 10873263001155 ()
  • 00873263001158 ()
FC4000

  • Depth electrode
  • Intracerebral cannula, implantable
microTargeting single electrode insertion tubes and electrodes kit, 5x, Sterile for use with NexFrame and NexDrive or mT Drive. Each Box Contains: 2x MTDPBN(PA)(DB2) Electrode. 1x IT(DB3) Insertion Tube with Stylet. 1x PT(DB5) Spacer Tube. Individual Specifications: MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm tip expsure, 234.3mm protective tube length, 0.56mm od, 1.0 meg. RZAP IT(DB3) - 194mm length, 1.8mm od, 1.6mm id. PT(DB5) - 194mm length, 1.47mm od, 0.99mm id.
FHC, INC.
FC4000-00753
In Commercial Distribution

  • 10873263007539 ()
  • 00873263007532 ()
FC4000

  • Intracerebral cannula, nonimplantable, single-use
  • Depth electrode
Guidline 4000 ™ 5.0 1.5m Special-use Lead, 1x For use with microTargeting ™ Electrodes
FHC, INC.
C0232-00781
In Commercial Distribution

  • 00873263007815 ()

  • Length: 1.5 Meter
C0232

  • Depth electrode
GL5 UE Patient Lead, 1.5m, presterile
FHC, INC.
C0231-00691
In Commercial Distribution

  • 00873263006917 ()

  • Length: 1.5 Meter
C0231

  • Depth electrode
GL5 UE Patient Lead, 3m, presterile
FHC, INC.
C0230-00690
In Commercial Distribution

  • 00873263006900 ()
C0230

  • Depth electrode
microTargeting Electrode Cable w/ Alligator Clips, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-01-00257
In Commercial Distribution

  • 00873263002575 ()
66-EL-EC-01

  • Depth electrode
microTargeting Electrode Cable, Sterile, for use with microTargeting Electrodes
FHC, INC.
66-EL-EC-00155
In Commercial Distribution

  • 00873263001554 ()
66-EL-EC

  • Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00151
In Commercial Distribution

  • 00873263001516 ()
FC1020

  • Depth electrode
microTargeting Electrode Cable
FHC, INC.
FC1020-00139
In Commercial Distribution

  • 00873263001394 ()
FC1020

  • Depth electrode
microTargeting™ Platform Platinum 6X Non Sterile
FHC, INC.
45335Z-00799
In Commercial Distribution

  • 10873263007997 ()
  • 00873263007990 ()

  • Length: 212.72 Millimeter
  • Impedance: Megaohms
  • Length: 3 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 220.72 Millimeter
45335Z

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, for use with Nexframe(R) and STar Drive
FHC, INC.
5730R-00579
In Commercial Distribution

  • 10873263005795 ()
  • 00873263005798 ()

  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 242.2 Millimeter
  • Length: 227.2 Millimeter
5730R

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, DZAP(L), for use with Nexframe(R)
FHC, INC.
5035L-00576
In Commercial Distribution

  • 10873263005764 ()
  • 00873263005767 ()

  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
5035L

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, for use with Nexframe(R)
FHC, INC.
5030R-00575
In Commercial Distribution

  • 10873263005757 ()
  • 00873263005750 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
5030R

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, single, D.ZAP(L), for use with Platform
FHC, INC.
44935L-00573
In Commercial Distribution

  • 10873263005733 ()
  • 00873263005736 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 205.7 Millimeter
  • Length: 220.7 Millimeter
  • Outer Diameter: 0.55 Millimeter
44935L

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, single, for use with Platform
FHC, INC.
44930R-00572
In Commercial Distribution

  • 10873263005726 ()
  • 00873263005729 ()

  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 220.7 Millimeter
  • Length: 205.7 Millimeter
44930R

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, single, T=30, for use with Frame and STar or MT Drive
FHC, INC.
34620R-00571
In Commercial Distribution

  • 10873263005719 ()
  • 00873263005712 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
34620R

  • Depth electrode
microTargeting(TM) Electrode, differential, nonsterile
FHC, INC.
MTDPXN(EP)(BP8)-00570
In Commercial Distribution

  • 10873263005702 ()
  • 00873263005705 ()

  • Length: 271.4 Millimeter
  • Length: 263.4 Millimeter
  • Outer Diameter: 0.86 Millimeter
  • Length: 3 Millimeter
MTDPXN(EP)(BP8)

  • Depth electrode