SEARCH RESULTS FOR: Origin(86 results)
Pedicle screw cross connect holder Class 1 instrument. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-1000T-113
In Commercial Distribution
- 00810005662550 ()
- General internal orthopaedic fixation system implantation kit
Small Ratchet Handle. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-1000T-111
In Commercial Distribution
- 00810005667234 ()
- General internal orthopaedic fixation system implantation kit
RETRACTABLE OSTEOTOME. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD
patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-O
In Commercial Distribution
- 00810135960649 ()
- Orthopaedic osteotome
EARP FINAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD
patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-FI
In Commercial Distribution
- 00810135960632 ()
- General internal orthopaedic fixation system implantation kit
EARP INITIAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD
patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-II
In Commercial Distribution
- 00810135960625 ()
- General internal orthopaedic fixation system implantation kit
EARP DISC RAKE
The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DR
In Commercial Distribution
- 00810135961042 ()
- Width: 35 Millimeter
- Depth: 22 Millimeter
- Height: 14 Millimeter
- General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X10 6°
The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0610
In Commercial Distribution
- 00810135960816 ()
- Width: 35 Millimeter
- Depth: 18 Millimeter
- Height: 10 Millimeter
- General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X08 0°
The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0008
In Commercial Distribution
- 00810135960809 ()
- Width: 35 Millimeter
- Depth: 18 Millimeter
- Height: 8 Millimeter
- General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X10 0°
The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0010
In Commercial Distribution
- 00810135960793 ()
- Depth: 14 Millimeter
- Width: 35 Millimeter
- Height: 10 Millimeter
- General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X08 0°
The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0008
In Commercial Distribution
- 00810135960786 ()
- Height: 8 Millimeter
- Depth: 14 Millimeter
- Width: 35 Millimeter