Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SEEG DEPTH ELECTRODE, 3x5 CONTACTS, EXPLORATION LENGTH 62MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000152 ()

  • Special Insulating Length between groups of 5 contacts 7 Millimeters
  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-15BM

  • Depth electrode
SEEG DEPTH ELECTRODE, 3x6 CONTACTS, EXPLORATION LENGTH 80.5MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000145 ()

  • Special Insulating Length between groups of 6 contacts 11 Millimeters
  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-18CT

  • Depth electrode
SEEG DEPTH ELECTRODE, 3x6 CONTACTS, EXPLORATION LENGTH 80.5MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000138 ()

  • Special Insulating Length between groups of 6 contacts 11 Millimeters
  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-18CM

  • Depth electrode
SEEG DEPTH ELECTRODE, 3x5 CONTACTS, EXPLORATION LENGTH 70MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000121 ()

  • Special Insulating Length between groups of 5 contacts 11 Millimeters
  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-15CT

  • Depth electrode
SEEG DEPTH ELECTRODE, 3x5 CONTACTS, EXPLORATION LENGTH 70MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000114 ()

  • Special Insulating Length between groups of 5 contacts 11 Millimeters
  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-15CM

  • Depth electrode
SEEG DEPTH ELECTRODE, 15 CONTACTS, EXPLORATION LENGTH 51MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000107 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-15AT

  • Depth electrode
SEEG DEPTH ELECTRODE, 15 CONTACTS, EXPLORATION LENGTH 51MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000091 ()

  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-15AM

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000084 ()

  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-12AT

  • Depth electrode
SEEG DEPTH ELECTRODE, 12 CONTACTS, EXPLORATION LENGTH 40.5MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000077 ()

  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-12AM

  • Depth electrode
SEEG DEPTH ELECTRODE, 10 CONTACTS, EXPLORATION LENGTH 33.5MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000060 ()

  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-10AT

  • Depth electrode
SEEG DEPTH ELECTRODE, 10 CONTACTS, EXPLORATION LENGTH 33.5MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000053 ()

  • Contact Length 2 Millimeters
  • Contact Spacing 3.5 Millimeters
D08-10AM

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000046 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-08AT

  • Depth electrode
SEEG DEPTH ELECTRODE, 8 CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000039 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-08AM

  • Depth electrode
SEEG DEPTH ELECTRODE, 5 CONTACTS, EXPLORATION LENGTH 16MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000022 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-05AT

  • Depth electrode
SEEG DEPTH ELECTRODE, 5 CONTACTS, EXPLORATION LENGTH 16MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000015 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-05AM

  • Depth electrode
SPHENOIDAL ELECTRODE EEG CABLE 1.5MM SOCKET SET
PMT CORPORATION
2122
In Commercial Distribution

  • 10650551092862 ()
  • 00650551092865 ()
2122

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE AND CABLE, NON-CRIMPED, 2 LOOSE CONNECTORS
PMT CORPORATION
2102-32-09
In Commercial Distribution

  • 10650551092855 ()
  • 00650551092858 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 22 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2102-32-09

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED, BLUE DEPTH STOP ON NEEDLE
PMT CORPORATION
2102-32-05
In Commercial Distribution

  • 10650551092848 ()
  • 00650551092841 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 22 Gauge
  • Recording Length 0.25 Inch
2102-32-05

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED
PMT CORPORATION
2102-32-03
In Commercial Distribution

  • 10650551092831 ()
  • 00650551092834 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 21 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2102-32-03

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, CRIMPED
PMT CORPORATION
2102-31-03
In Commercial Distribution

  • 10650551092824 ()
  • 00650551092827 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 21 Gauge
  • Recording Length 0.25 Inch
2102-31-03

  • Depth electrode
STAINLESS STEEL ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED
PMT CORPORATION
2101-32-03
In Commercial Distribution

  • 10650551092817 ()
  • 00650551092810 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 21 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2101-32-03

  • Depth electrode
STAINLESS STEEL ELECTRODE, WITH NEEDLE, WITHOUT CABLE, CRIMPED
PMT CORPORATION
2101-31-03
In Commercial Distribution

  • 10650551092800 ()
  • 00650551092803 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 21 Gauge
  • Recording Length 0.25 Inch
2101-31-03

  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
EDSEP
Not in Commercial Distribution

  • M272EDSEP1 ()
  • 10381780037088 ()


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D5L25
Not in Commercial Distribution

  • M272AU8D5L251 ()
  • 10381780036531 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L5
Not in Commercial Distribution

  • M272AU8D10L51 ()
  • 10381780036524 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L25
Not in Commercial Distribution

  • M272AU8D10L251 ()
  • 10381780036517 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D5L25
Not in Commercial Distribution

  • M272AU6D5L251 ()
  • 10381780036456 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L5
Not in Commercial Distribution

  • M272AU6D10L51 ()
  • 10381780036449 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L25
Not in Commercial Distribution

  • M272AU6D10L251 ()
  • 10381780036432 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D5L25
Not in Commercial Distribution

  • M272AU4D5L251 ()
  • 10381780036326 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
Not in Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L25
Not in Commercial Distribution

  • M272AU4D10L251 ()
  • 10381780036302 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
40M08
Not in Commercial Distribution

  • M27240M081 ()
  • 10381780034766 ()

  • Insertion needle 64mm Length


  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
NeuroProbe
In Commercial Distribution

  • 17290014954974 ()
  • 07290014954977 ()
STR-94685Z-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
NeuroProbe
In Commercial Distribution

  • 17290014954967 ()
  • 07290014954960 ()
STR-94685L-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Sterile Neuro Omega AlphaProbe electrode's cable 10 CH
In Commercial Distribution

  • 17290014954950 ()
  • 07290014954953 ()
STR-000664-21

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
NeuroProbe
In Commercial Distribution

  • 17290014954943 ()
  • 07290014954946 ()
STR-AP9080-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Shielded
In Commercial Distribution

  • 17290014954875 ()
  • 07290014954878 ()
STR-050925-00

  • Depth electrode