Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

3 Level, 69mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-69
In Commercial Distribution

  • 111106369 ()
  • M364111106FD3690 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 66mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-66
In Commercial Distribution

  • 111106366 ()
  • M364111106FD3660 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 63mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-63
In Commercial Distribution

  • 111106363 ()
  • M364111106FD3630 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 60mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-60
In Commercial Distribution

  • 111106360 ()
  • M364111106FD3600 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 57mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-57
In Commercial Distribution

  • 111106357 ()
  • M364111106FD3570 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 54mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-54
In Commercial Distribution

  • 111106354 ()
  • M364111106FD3540 ()


  • Spinal fixation plate, non-bioabsorbable
3 Level, 51mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD3-51
In Commercial Distribution

  • 111106351 ()
  • M364111106FD3510 ()


  • Spinal fixation plate, non-bioabsorbable
2 Level, 35mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD2-35
In Commercial Distribution

  • 111106235 ()
  • M364111106FD2350 ()


  • Spinal fixation plate, non-bioabsorbable
Set Screw. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
S-00-001
In Commercial Distribution

  • 00814008027613 ()


  • Bone-screw internal spinal fixation system, non-sterile
Rod, MIS, Lordotic 5.5X130mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
M-01-130
In Commercial Distribution

  • 00814008029730 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 130 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile