Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-20V
In Commercial Distribution

  • 90814008023847 ()

  • Height: 20 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-475-14V
In Commercial Distribution

  • 90814008023809 ()

  • Height: 14 Millimeter
  • Width: 4.75 Millimeter
  • Depth: 4.75 Millimeter
ACP-475-14V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12V
In Commercial Distribution

  • 90814008023748 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12F
In Commercial Distribution

  • 90814008023625 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3.75mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-375-12F
In Commercial Distribution

  • 90814008023564 ()

  • Height: 12 Millimeter
  • Width: 3.75 Millimeter
  • Depth: 3.75 Millimeter
ACP-375-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-80
In Commercial Distribution

  • 90814008023519 ()

  • Height: 80 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-80

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-68
In Commercial Distribution

  • 90814008023489 ()

  • Height: 68 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-68

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-74
In Commercial Distribution

  • 90814008023441 ()

  • Height: 74 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-74

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-62
In Commercial Distribution

  • 90814008023403 ()

  • Height: 62 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-62

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-51
In Commercial Distribution

  • 90814008023359 ()

  • Height: 51 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-33
In Commercial Distribution

  • 90814008023298 ()

  • Height: 33 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-2-33

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 1 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-1-34
In Commercial Distribution

  • 90814008023281 ()

  • Height: 34 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-1-34

  • Intervertebral-body internal spinal fixation system
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00133
Not in Commercial Distribution

  • 00873263001332 ()
KTF1001

  • Patient surgical drape, single-use
  • Intracerebral cannula, implantable
  • Depth electrode
microTargeting Platform Procedure Consumables Kit, 1x, sterile, for use with mT or STar Drive, mT Platform and Guideline 4000 LP+. Contains: 44975L: D.ZAP Tungsten Differential Electrode - - 220.72mm electrode length, 10mm differential, 205.72mm protective tube length, DZAP(L) 1Meg, 0.55mm od. 66-DA-SD: Sterile Drape Sleeve for motor 66-EL-LP: Patient Lead for Guideline 4000 LP+ 66-IT-03P: Sterile Single Insertion Tube Set - IT(MP1) - 184.1mm tube length, 1.83mm od, 1.6mm id with Stylet PT(MP1) - Diameter reduction tube 0.58mm id
FHC, INC.
KT-PPK-S-00366
In Commercial Distribution

  • 00873263003664 ()
KT-PPK-S

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, implantable
microTargeting Frame Kit D.ZAP/Lead Insertion, 1x, Sterile, for use with mT Drive or STar Drive. Contains: 34685L: Single D.ZAP Electrode. 66-DA-SD: Drape Sleeve. 66-EL-LP: Patient Lead for LP+. 66-IT-05P: Single Insertion Tube Set.
FHC, INC.
KT-FPK-S20-00508
In Commercial Distribution

  • 00873263005088 ()
KT-FPK-S20

  • Depth electrode
  • Neurological stereotactic surgery system
  • Intracerebral cannula, implantable
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00134
Not in Commercial Distribution

  • 10873263001346 ()
  • 00873263001349 ()
KTF1002

  • Intracerebral cannula, implantable
  • Depth electrode
Array Insertion Electrode/Tube with Stylet Kit, 5x, Sterile, for use with Nexframe and microTargeting Drive. Contains: IT(AR8): Insertion Tube w/ Stylet. MTDPBN(PA)(DB2): microTargeting Electrode. Individual Specifications: IT(AR8) - 217mm tube length, 0.89mm OD, 0.58mm ID MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm differential length, 234.2mm protective tube length. 1 Meg RZAP, 0.56mm od
FHC, INC.
FC7100-00132
Not in Commercial Distribution

  • 10873263001322 ()
  • 00873263001325 ()
FC7100

  • Intracerebral cannula, implantable
  • Depth electrode
microTargeting D.ZAP Electrode Kit, 5x, Sterile, Single, 1 Meg, for use with NexFrame and NexDrive or mT Drive. Each box contains: 2x MTDPLN(PA)(DB2) D.ZAP Differential Electrode. 1x IT(DB3) Insertion tube with Stylet. 1x PT(DB5) Protective Tube. Individual Specifications: MTDPLN(PA)(DB2) - 249.2mm electrode length, 10mm tip exposure, 234.2mm protective tube length, .56mm od, 1.0 meg DZAP(L) IT(DB3) - 194mm length, 1.8mm od, 1.6mm id, PT(DB5) - 194mm length, 1.47mm od, 0.99mm id
FHC, INC.
FC4001-00116
Not in Commercial Distribution

  • 10873263001162 ()
  • 00873263001165 ()
FC4001

  • Depth electrode
  • Intracerebral cannula, implantable
microTargeting single electrode insertion tubes and electrodes kit, 5x, Sterile for use with NexFrame and NexDrive or mT Drive. Each Box Contains: 2x MTDPBN(PA)(DB2) Electrode. 1x IT(DB3) Insertion Tube with Stylet. 1x PT(DB5) Spacer Tube. Individual Specifications: MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm tip expsure, 234.3mm protective tube length, 0.56mm od, 1.0 meg. RZAP IT(DB3) - 194mm length, 1.8mm od, 1.6mm id. PT(DB5) - 194mm length, 1.47mm od, 0.99mm id.
FHC, INC.
FC4000-00115
Not in Commercial Distribution

  • 10873263001155 ()
  • 00873263001158 ()
FC4000

  • Depth electrode
  • Intracerebral cannula, implantable
XenoSure Thick Biologic Patch, 10 x 16cm - eP
Lemaitre Vascular, Inc.
e10P16T
In Commercial Distribution

  • 00840663109227 ()
e10P16T

  • Cardiovascular patch, animal-derived
XenoSure Thick Biologic Patch, 6 x 8cm - eP
Lemaitre Vascular, Inc.
e6P8T
In Commercial Distribution

  • 00840663109210 ()
e6P8T

  • Cardiovascular patch, animal-derived
XenoSure Biologic Pledgets, 0.5cm x 1.0cm
Lemaitre Vascular, Inc.
PL0510R25
In Commercial Distribution

  • 00840663109357 ()
PL0510R25

  • Cardiovascular patch, animal-derived
XenoSure Biologic Pledgets, 0.5cm x 0.6cm, 25-Count
Lemaitre Vascular, Inc.
PL0506R25
In Commercial Distribution

  • 00840663109340 ()
PL0506R25

  • Cardiovascular patch, animal-derived
XenoSure Biologic Pledgets, 0.3cm x 0.7cm
Lemaitre Vascular, Inc.
PL0307R25
In Commercial Distribution

  • 00840663109333 ()
PL0307R25

  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 6cm x 8cm, eIFU
Lemaitre Vascular, Inc.
e6P8
In Commercial Distribution

  • 00840663106806 ()
e6P8

  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 0.6cmx8cm
Lemaitre Vascular, Inc.
0.6BV8
In Commercial Distribution

  • 00840663106745 ()


  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 8cm x 14cm, eIFU
Lemaitre Vascular, Inc.
e8P14
In Commercial Distribution

  • 00840663106332 ()
e8P14

  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 4cm x 6cm, eIFU
Lemaitre Vascular, Inc.
e4P6
In Commercial Distribution

  • 00840663106325 ()
e4P6

  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 4cm x 4cm, eIFU
Lemaitre Vascular, Inc.
e4P4
In Commercial Distribution

  • 00840663106318 ()
e4P4

  • Cardiovascular patch, animal-derived
XenoSure Biologic Patch, 2cm x 9cm, eIFU
Lemaitre Vascular, Inc.
e2P9
In Commercial Distribution

  • 00840663106301 ()
e2P9

  • Cardiovascular patch, animal-derived