SEARCH RESULTS FOR: (*cvs Heating pads*)(8 results)
The BSD-2000 system is a prescription device that is intended to deliver hyperthermia, which has been shown to increase the sensitivity of tumor cells to radiation or chemotherapy by the external application of electromagnetic energy. The system provides hyperthermia to solid tumors by generating and applying radio frequency (RF) energy.
Pyrexar Medical Inc.
BSD-2000U
- Microwave hyperthermia system
The BSD-2000 system is a prescription device that is intended to deliver hyperthermia, which has been shown to increase the sensitivity of tumor cells to radiation or chemotherapy by the external application of electromagnetic energy. The system provides hyperthermia to solid tumors by generating and applying radio frequency (RF) energy.
Pyrexar Medical Inc.
BSD-2000B
- Microwave hyperthermia system
Deep Hyperthermia System (U.S.A.)
BSD MEDICAL CORPORATION
BSD-2000U
Not in Commercial Distribution
- 00851551005187 ()
- Tumour-therapy radio-frequency hyperthermia system
Deep Hyperthermia System (U.S.A.)
BSD MEDICAL CORPORATION
BSD-2000B
Not in Commercial Distribution
- 00851551005170 ()
- Tumour-therapy radio-frequency hyperthermia system
The BSD-2000 system is a prescription device that is intended to deliver hyperthermia, which has been shown to increase the sensitivity of tumor cells to radiation or chemotherapy by the external application of electromagnetic energy. The system provides hyperthermia to solid tumors by generating and applying radio frequency (RF) energy.
Pyrexar Medical Inc.
BSD-2000U
- Microwave hyperthermia system
The BSD-2000 system is a prescription device that is intended to deliver hyperthermia, which has been shown to increase the sensitivity of tumor cells to radiation or chemotherapy by the external application of electromagnetic energy. The system provides hyperthermia to solid tumors by generating and applying radio frequency (RF) energy.
Pyrexar Medical Inc.
BSD-2000B
- Microwave hyperthermia system
CliniMACS® Tubing Set (LS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73205
In Commercial Distribution
- 04049934004841 ()
162-01
- Magnetic cell separation system tubing set
CliniMACS® Tubing Set (TS) is a single-use, sterile, disposable tubing set with two proprietary cell separation columns used as part of the CliniMACS CD34 Reagent System. The CliniMACS® CD34 Reagent System is an in vitro medical device system used to select and enrich CD34+ cells from HPC, Apheresis while passively depleting other cells, such as CD3+ T cells, which cause graft versus host disease. The system is based on "magnetically-activated cell sorting" (MACS) employing antibodies conjugated to iron-containing particles that can be attracted to a magnetic field (referred to as “magnetic labeling”). Using the specificity of anti-CD34 antibody interaction with cell surface CD34 antigen found on hematopoietic progenitor cells, the system enriches CD34+ cells from HPC, Apheresis by passing the antibody-labeled cell suspension through a separation column with a strong magnetic gradient. The separation column retains the magnetically labeled CD34+ target cells while unlabeled cells flow through and are collected in the Negative Fraction Bag. Several automated washing steps are performed, disposing most of the liquid into the Buffer Waste Bag. The magnetically-selected CD34+ cells are released from the separation column when the magnet is disengaged, removing the magnetic field, and the target CD34+ cells are eluted into the Cell Collection Bag.
Miltenyi Biotec B.V. & Co. KG
73105
In Commercial Distribution
- 04049934004834 ()
161-01
- Magnetic cell separation system tubing set
1