Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

EARP, TRIAL 22X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-2235-0610
In Commercial Distribution

  • 00810135960861 ()

  • Width: 35 Millimeter
  • Depth: 22 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1214
In Commercial Distribution

  • 00810135960854 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 12° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-1212
In Commercial Distribution

  • 00810135960847 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X14 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0614
In Commercial Distribution

  • 00810135960830 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X12 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0612
In Commercial Distribution

  • 00810135960823 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 12 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X10 6° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0610
In Commercial Distribution

  • 00810135960816 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 18X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1835-0008
In Commercial Distribution

  • 00810135960809 ()

  • Width: 35 Millimeter
  • Depth: 18 Millimeter
  • Height: 8 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X10 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0010
In Commercial Distribution

  • 00810135960793 ()

  • Depth: 14 Millimeter
  • Width: 35 Millimeter
  • Height: 10 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X35X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1435-0008
In Commercial Distribution

  • 00810135960786 ()

  • Height: 8 Millimeter
  • Depth: 14 Millimeter
  • Width: 35 Millimeter


  • General internal orthopaedic fixation system implantation kit
EARP, TRIAL 14X25X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-T-1425-0008
In Commercial Distribution

  • 00810135960779 ()

  • Height: 8 Millimeter
  • Width: 25 Millimeter
  • Depth: 14 Millimeter


  • General internal orthopaedic fixation system implantation kit
RETRACTABLE OSTEOTOME. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-O
In Commercial Distribution

  • 00810135960649 ()


  • Orthopaedic osteotome
EARP FINAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-FI
In Commercial Distribution

  • 00810135960632 ()


  • General internal orthopaedic fixation system implantation kit
EARP INITIAL INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-II
In Commercial Distribution

  • 00810135960625 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER INSERTER. The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-002
In Commercial Distribution

  • 00810135960618 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 14MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-14
In Commercial Distribution

  • 00810135960601 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 12MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-12
In Commercial Distribution

  • 00810135960595 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 10MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-10
In Commercial Distribution

  • 00810135960588 ()


  • General internal orthopaedic fixation system implantation kit
EARP DISC SPACER 8MM The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP-DS-001-08
In Commercial Distribution

  • 00810135960571 ()


  • General internal orthopaedic fixation system implantation kit
EARP, 14X25X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP1425-0008
In Commercial Distribution

  • 00810135960007 ()

  • Depth: 14 Millimeter
  • Width: 25 Millimeter
  • Height: 8 Millimeter


  • Polymeric spinal interbody fusion cage
Graft Packing & Screw Reference Block
TITAN SPINE, LLC
2300-1317
Not in Commercial Distribution

  • 00191375028338 ()

  • Width: 1.5 Inch
  • Length: 2 Inch
  • Height: 1.25 Inch
2300-1317

  • Bone graft packing block
Graft Packing & Screw Reference Block
TITAN SPINE, LLC
5210-1017
Not in Commercial Distribution

  • 00191375028345 ()

  • Height: 1 Inch
  • Width: 2 Inch
  • Length: 1.5 Inch
5210-1017

  • Bone graft packing block
EVOL®ha-C Cervical Bone Packing Block
Cutting Edge Spine, LLC
CES-472
In Commercial Distribution

  • 00841193121246 ()

  • Length: 50 Millimeter
CES-472

  • Bone graft packing block
Rod, Lordotic 5.5X95mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion5
NVISION BIOMEDICAL TECHNOLOGIES, INC.
L-01-095
In Commercial Distribution

  • 00810005667241 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 95 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
Small Ratchet Handle. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-1000T-111
In Commercial Distribution

  • 00810005667234 ()


  • General internal orthopaedic fixation system implantation kit
Pedicle screw cross connect holder Class 1 instrument. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-1000T-113
In Commercial Distribution

  • 00810005662550 ()


  • General internal orthopaedic fixation system implantation kit
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-030
In Commercial Distribution

  • 00814008026814 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-025
In Commercial Distribution

  • 00814008026807 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X60mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-060
In Commercial Distribution

  • 00814008026791 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 60 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X55mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-055
In Commercial Distribution

  • 00814008026784 ()

  • Length: 55 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X45mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-045
In Commercial Distribution

  • 00814008026760 ()

  • Length: 45 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X35mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-035
In Commercial Distribution

  • 00814008026746 ()

  • Length: 35 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-025
In Commercial Distribution

  • 00814008026722 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-030
In Commercial Distribution

  • 00814008026579 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-025
In Commercial Distribution

  • 00814008026562 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 5.5X55mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-550-055
In Commercial Distribution

  • 00814008026555 ()

  • Length: 55 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-550-050
In Commercial Distribution

  • 00814008026548 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X60mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-060
In Commercial Distribution

  • 00814008026395 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 60 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-050
In Commercial Distribution

  • 00814008026371 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X45mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-045
In Commercial Distribution

  • 00814008026364 ()

  • Length: 45 Millimeter
  • Outer Diameter: 4.75 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X40mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-040
In Commercial Distribution

  • 00814008026357 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 40 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
< 1 ... 15 16 17 18 19 ... 40 >