Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

FREND™ Testosterone Linearity Kit is intended for use as an assayed linearity material for the testosterone on the FREND™ System. The Linearity Kit is for the FREND™ System only. FREND™ Testosterone Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution
NanoEnTek, Inc.
FREND Testosterone Linearity Kit
In Commercial Distribution

  • 08809317540542 ()
FLK-TES

  • Non-blood cell primer/calibrator/control material IVD, reagent
FREND™ TSH Linearity Kit is intended for use as an assayed linearity material for the thyroid stimulating hormone (TSH) on the FREND™ System. The Linearity Kit is for the FREND™ System only. FREND™ TSH Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
NanoEnTek, Inc.
FREND TSH Linearity Kit
In Commercial Distribution

  • 08809317540559 ()
FLK-TSH

  • Non-blood cell primer/calibrator/control material IVD, reagent
FREND™ PSA Plus Linearity Kit is intended for use as an assayed linearity material for the prostate-specific antigen (PSA) on the FREND™ System. The Linearity kit is for the FREND™ System only. FREND™ PSA Plus Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
NanoEnTek, Inc.
FREND PSA Plus Linearity Kit
In Commercial Distribution

  • 08809317540535 ()
FLK-PSA

  • Non-blood cell primer/calibrator/control material IVD, reagent
FREND™ Free T4 Linearity Kit is intended for use as an assayed linearity material for the free thyroxine (Free T4) on the FREND™ System. The Linearity Kit is for the FREND™ System only. FREND™ Free T4 Linearity Kit is provided at five levels to assist in the checking of analytical systems within the clinical range. The kit is horse serum-based containing constituents of human origin as well as purified chemicals. Preservatives and stabilizers have been added to maintain product integrity. The kit is a ready-to-use liquid requiring no reconstitution.
NanoEnTek, Inc.
FREND Free T4 Linearity Kit
In Commercial Distribution

  • 08809317540528 ()
FLK-FT4

  • Non-blood cell primer/calibrator/control material IVD, reagent
Smoke Filtration System (230 Volts AC)
UTAH MEDICAL PRODUCTS, INC.
230VAC
In Commercial Distribution

  • H671SSE2000 ()
SSE-200

  • Surgical plume evacuation system
Smoke Filtration System (115 Volts AC)
UTAH MEDICAL PRODUCTS, INC.
115VAC
In Commercial Distribution

  • H671SSE1000 ()
SSE-100

  • Surgical plume evacuation system
No Description
Synapse Biomedical, Inc.
22-0020
In Commercial Distribution

  • 00852184003380 ()


  • Intramuscular diaphragm/phrenic nerve electrical stimulation system
Portable Cart for Smoke Evacuators
Buffalo Filter
ETC01
Not in Commercial Distribution

  • 00851136002396 ()


  • Surgical plume evacuation system
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures approximately 50 cm2 in area. Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
0
In Commercial Distribution

  • W41020AU201P0001 ()

  • Area/Surface Area: 50 Square centimeter


  • Cultured skin autograft/xenograft
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures a minimum of 50 cm2 in area. Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
N/A
In Commercial Distribution

  • W41020AU201S1969 ()

  • Area/Surface Area: 50 Square centimeter


  • Cultured skin autograft/xenograft
No Description
Synapse Biomedical, Inc.
22-0034
In Commercial Distribution

  • 00852184003465 ()


  • Intramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Synapse Biomedical, Inc.
22-0018
In Commercial Distribution

  • 00852184003373 ()


  • Intramuscular diaphragm/phrenic nerve electrical stimulation system
EKSO BIONICS SYSTEM, Ekso NR
EKSO BIONICS, INC.
EKSONR
In Commercial Distribution

  • B168EKSONR0 ()
EKSONR

  • Programmable ambulation exoskeleton, clinical
EKSO BIONICS SYSTEM, Ekso GT
EKSO BIONICS, INC.
EKSOGT
In Commercial Distribution

  • B168EKSOGT0 ()
EKSOGT

  • Programmable ambulation exoskeleton, clinical
The Ekso is a powered motorized orthosis. It consists of a fitted metal brace that supports the legs, feet, and torso. It is worn via straps on the body, legs, and feet. Battery powered motors drive knee and hip joints. It has an integrated solid torso containing the computer and power supply. It has a hand-held user interface to specify settings and initiate steps. The Ekso is used with a cane, crutch, or walker.
EKSO BIONICS, INC.
GT
In Commercial Distribution

  • B1431200000 ()


  • Programmable ambulation exoskeleton, clinical
EasyVac Kit (1) EASYVAC 120V, (1) VSTR08, (1) EZLINK01, (1) FS10004, (3) S-PA2010, (2) BLAP100V, (3) S-VTWT624
Conmed Corporation
EASYVACKIT
In Commercial Distribution

  • 30845854081017 ()
EASYVACKIT

  • Surgical plume evacuation system
No Description
I.C. MEDICAL, INC.
2250
Not in Commercial Distribution

  • 00817688021742 ()
ICM-000-0422

  • Surgical plume evacuation system
No Description
I.C. MEDICAL, INC.
ICM-000-0009
In Commercial Distribution

  • 00817688021711 ()


  • Surgical plume evacuation system
ELVIS MWP W24/24F W/CS
DIAGNOSTIC HYBRIDS, INC.
55-2424S
In Commercial Distribution

  • 30014613333098 ()
55-2424S

  • Cell culture line IVD
ELVIS MWP W24/24F
DIAGNOSTIC HYBRIDS, INC.
55-2424
In Commercial Distribution

  • 30014613333081 ()
55-2424

  • Cell culture line IVD
< 1 ... 45 46 47 48 49 ... 59 >