Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-20V
In Commercial Distribution

  • 90814008023847 ()

  • Height: 20 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-475-14V
In Commercial Distribution

  • 90814008023809 ()

  • Height: 14 Millimeter
  • Width: 4.75 Millimeter
  • Depth: 4.75 Millimeter
ACP-475-14V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12V
In Commercial Distribution

  • 90814008023748 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12F
In Commercial Distribution

  • 90814008023625 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3.75mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-375-12F
In Commercial Distribution

  • 90814008023564 ()

  • Height: 12 Millimeter
  • Width: 3.75 Millimeter
  • Depth: 3.75 Millimeter
ACP-375-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-80
In Commercial Distribution

  • 90814008023519 ()

  • Height: 80 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-80

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-68
In Commercial Distribution

  • 90814008023489 ()

  • Height: 68 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-68

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-74
In Commercial Distribution

  • 90814008023441 ()

  • Height: 74 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-74

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-62
In Commercial Distribution

  • 90814008023403 ()

  • Height: 62 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-62

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-51
In Commercial Distribution

  • 90814008023359 ()

  • Height: 51 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-33
In Commercial Distribution

  • 90814008023298 ()

  • Height: 33 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-2-33

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 1 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-1-34
In Commercial Distribution

  • 90814008023281 ()

  • Height: 34 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-1-34

  • Intervertebral-body internal spinal fixation system
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-170-NS
In Commercial Distribution

  • 00650551148722 ()


  • Depth electrode
PLATINUM sEEG ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-169-NS
In Commercial Distribution

  • 00650551148715 ()


  • Depth electrode
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-171-NS
In Commercial Distribution

  • 00650551148739 ()


  • Depth electrode
TROUGH EX0910177 BONE GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0910177
In Commercial Distribution

  • 00613994933423 ()


  • Bone graft packing block
TROUGH EX0810836 BONE GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0810836
In Commercial Distribution

  • 00613994933409 ()


  • Bone graft packing block
PACKING STATION EX0818003 GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0818003
In Commercial Distribution

  • 00763000216948 ()


  • Bone graft packing block
STATION EX0220045 GRAFT PACKING
MEDTRONIC SOFAMOR DANEK, INC.
EX0220045
In Commercial Distribution

  • 00763000371777 ()


  • Bone graft packing block
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(LS)(LS3)-00386
In Commercial Distribution

  • 10873263003869 ()
  • 00873263003862 ()

  • Length: 291.5 Millimeter
  • Length: 273.5 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
MTDWBN(LS)(LS3)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(BP)(BP7)-00384
In Commercial Distribution

  • 10873263003845 ()
  • 00873263003848 ()

  • Length: 256.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
MTDWBN(BP)(BP7)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, non sterile
FHC, INC.
MTDWBN(BP)(BP6)-00382
In Commercial Distribution

  • 10873263003821 ()
  • 00873263003824 ()

  • Length: 227 Millimeter
  • Length: 277 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
MTDWBN(BP)(BP6)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(BP)(BP5)-00380
In Commercial Distribution

  • 10873263003807 ()
  • 00873263003800 ()

  • Length: 215 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 265 Millimeter
  • Outer Diameter: 0.77 Millimeter
MTDWBN(BP)(BP5)

  • Depth electrode
microTargeting Electrode, differential, tungsten, non-sterile
FHC, INC.
MTDWBN(AR)(AR2)-00375
In Commercial Distribution

  • 10873263003753 ()
  • 00873263003756 ()

  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
MTDWBN(AR)(AR2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(AO)(AO1)-00372
In Commercial Distribution

  • 10873263003722 ()
  • 00873263003725 ()

  • Length: 282 Millimeter
  • Outer Diameter: 1.27 Millimeter
  • Impedance: Megaohms
  • Length: 3 Millimeter
  • Length: 274 Millimeter
MTDWBN(AO)(AO1)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(AO)(A10)-00363
In Commercial Distribution

  • 10873263003630 ()
  • 00873263003633 ()

  • Length: 242 Millimeter
  • Length: 210 Millimeter
  • Outer Diameter: 1.27 Millimeter
  • Length: 27 Millimeter
  • Impedance: Megaohms
MTDWBN(AO)(A10)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWAN(AR)(AR1)-00360
Not in Commercial Distribution

  • 10873263003609 ()
  • 00873263003602 ()

  • Impedance: Megaohms
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 3 Millimeter
  • Length: 268.5 Millimeter
MTDWAN(AR)(AR1)

  • Depth electrode
microTargeting(TM) Electrode, differential, platinum/iridium, glass insulated DZAP(Z), non-sterile
FHC, INC.
MTDPZN(BP)(BP7)-00343
In Commercial Distribution

  • 10873263003432 ()
  • 00873263003435 ()

  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Outer Diameter: 0.86 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
MTDPZN(BP)(BP7)

  • Depth electrode
microTargeting(TM) Electrode, differential, platinum/iridium, glass insulated, specify Z, nonsterile
FHC, INC.
MTDPXN(SP)(AO9)-00335
In Commercial Distribution

  • 10873263003357 ()
  • 00873263003350 ()

  • Length: 1 Millimeter
  • Length: 235.86 Millimeter
  • Length: 241.86 Millimeter
  • Outer Diameter: 1.24 Millimeter
MTDPXN(SP)(AO9)

  • Depth electrode
microTargeting(TM) Electrode, differential, platinum/iridium, glass insulated, specify Z, nonsterile
FHC, INC.
MTDPXN(BP)(BP7)-00330
In Commercial Distribution

  • 10873263003302 ()
  • 00873263003305 ()

  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.86 Millimeter
MTDPXN(BP)(BP7)

  • Depth electrode
< 1 2 3 4 5 ... 56 >