1 Level, 20mm Cervical Plate; The Asfora Anterior Cervical Plate System is intended to provide temporary stabilization to the anterior spine during the development of cervical spine fusions (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudoarthrosis, and failed previous fusion.
MEDICAL DESIGNS LLC
11-1106-FD1-20
In Commercial Distribution

  • M364111106FD1200 ()
  • 111106120 ()


  • Spinal fixation plate, non-bioabsorbable
The Atalante X by Wandercraft is a completely self-balancing walking system for people with mobility disabilities. It is a fully powered hip-knee-ankle lower body exoskeleton with 12 actuated degrees of freedom. Atalante X is self-balancing and includes dynamic-walking control. Dynamic walking allows the Atalante X to consume significantly less power and have a more natural gait. The Atalante X is a tool for physical therapy. It is meant to be highly adjustable and be applicable for various stages of physical rehabilitation, re-mobilization and exercises.
WANDERCRAFT
ATA-002-EN US
In Commercial Distribution

  • 03665965000129 ()


  • Programmable ambulation exoskeleton, clinical
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Autoclavable Drive
In Commercial Distribution

  • 07290114063296 ()
750-000027-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Rev. 4
In Commercial Distribution

  • 07290114060899 ()
750-000027-00

  • Depth electrode
No Description
Avery Biomedical Devices Inc
Transtelephonic Monitor
Not in Commercial Distribution

  • 00850252006059 ()
TTM

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
(902A) 1.0 m Lead Length
Avery Biomedical Devices Inc
External Antenna
In Commercial Distribution

  • 00850252006035 ()
902A

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Receiver Implant
In Commercial Distribution

  • 00850252006011 ()
I-110A

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
Digital Transmitter for the Avery Breathing Pacemaker System
Avery Biomedical Devices Inc
NeurostimulatorTransmitter Digital
In Commercial Distribution

  • 00850252006066 ()
Spirit

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
(902A) 2.0 m Lead Length
Avery Biomedical Devices Inc
External Antenna
In Commercial Distribution

  • 00850252006042 ()
902AL

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Electrode Implant
In Commercial Distribution

  • 00850252006028 ()
E377-05

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Transmitter
In Commercial Distribution

  • 00850252006004 ()
MARK IV

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
ALIMED, INC.
7025720
In Commercial Distribution

  • 00733657242645 ()
  • 00733657299533 ()
2970008131

  • Movement-resistance gait rehabilitation device
No Description
ALIMED, INC.
7414
In Commercial Distribution

  • 00733657223996 ()
2970009877

  • Movement-resistance gait rehabilitation device
No Description
ALIMED, INC.
77905
In Commercial Distribution

  • 00733657229271 ()
2970010245

  • Movement-resistance gait rehabilitation device
No Description
ALIMED, INC.
3123
In Commercial Distribution

  • 00733657284690 ()
2970000595

  • Movement-resistance gait rehabilitation device
BENGAL SYSTEM BONE FILLER BLOCK, EXTRA LARGE
DEPUY SPINE, LLC
273310301
In Commercial Distribution

  • 10705034188065 ()
273310301

  • Bone graft packing block
BENGAL STACKABLE CAGE SYSTEM CAGE FILLER BLOCK
DEPUY SPINE, LLC
277308000
In Commercial Distribution

  • 10705034197692 ()
277308000

  • Bone graft packing block
BENGAL SYSTEM FILLER BLOCK
DEPUY SPINE, LLC
273310300
In Commercial Distribution

  • 10705034188058 ()
273310300

  • Bone graft packing block
No Description
ALIMED, INC.
710132
In Commercial Distribution

  • 00733657230604 ()
  • 00733657299274 ()
2970008477

  • Movement-resistance gait rehabilitation device
The BabyG Early Mobilization System is a robotic body-weight support system which automatically tracks patients as they move freely in any direction. The dynamic body-weight support offloads a percentage of the patient’s weight as they perform activities in a full 3-dimensional workspace, while the advanced fall protection provides the highest level of safety. The BabyG System is intended to assist subjects weighing 50 pounds or less as they practice therapeutic activities related to walking and balance activities. BabyG should never be used to lift and transport subjects and should never be connected to inanimate objects. BabyG should only be operated by therapists and trained healthcare professionals who have read and understand the instructions for use and have passed the BabyG training competency exam conducted by an Aretech trainer or a certified staff trainer.
ARETECH, LLC
BG-001
In Commercial Distribution

  • 00850018836258 ()


  • Gait rehabilitation frame, electric
Balance harness for balance training activities
M.A.S.S. Rehab, LLC
Standard
In Commercial Distribution

  • G505MRBHS0 ()


  • Gait rehabilitation system harness
Unit for storing and recharging the inFlow Activator
VESIFLO INC
August 2021
In Commercial Distribution

  • 00862563003160 ()
403310

  • Intraurethral valve/pump
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
BenGun and Microelectrode holder screws
In Commercial Distribution

  • 07290114061315 ()
344-000056-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Bengun Adapter
In Commercial Distribution

  • 07290114064156 ()
352-000212-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Bengun W/O Screws
In Commercial Distribution

  • 07290114064149 ()
700-000307-01

  • Depth electrode
BIOFEEDBACK DEVICE BioRef-DC
TAVGER LTD
FG00019
In Commercial Distribution

  • 07290017249049 ()


  • Intramuscular diaphragm/phrenic nerve electrical stimulation system
Gamma Camera System
Ddd-Diagnostic A/S
BodyMD Gamma Camera System
Not in Commercial Distribution

  • 05711665003026 ()

  • Width: 291 Centimeter
  • Depth: 197 Centimeter
  • Height: 225 Centimeter
  • Weight: 2144 Kilogram
9PMS3131

  • Stationary gamma camera system
Gamma Camera System
Ddd-Diagnostic A/S
QuantumCam Gamma Camera System
In Commercial Distribution

  • 05711665003019 ()

  • Width: 291 Centimeter
  • Depth: 197 Centimeter
  • Height: 225 Centimeter
  • Weight: 2144 Kilogram
9PMS3131

  • Stationary gamma camera system
SMOKE EVACUATOR ARTICULATED, ARMSTAND WITH FASTENERS
BOVIE MEDICAL CORPORATION
SEAS
In Commercial Distribution

  • 10607151065161 ()
SEAS

  • Surgical plume evacuation system
BOVIE EZ LINK
BOVIE MEDICAL CORPORATION
SERS2
In Commercial Distribution

  • 10607151008496 ()
SERS2

  • Surgical plume evacuation system
SMOKE SHARK II 120V-220V - SMOKE EVACUATOR
BOVIE MEDICAL CORPORATION
SE02-220
In Commercial Distribution

  • 10607151008304 ()
SE02-220

  • Surgical plume evacuation system
SMOKE SHARK II 120 V - SMOKE EVACUATOR
BOVIE MEDICAL CORPORATION
SE02
In Commercial Distribution

  • 10607151008298 ()
SE02

  • Surgical plume evacuation system
PNEUMATIC FOOTSWITCH - SMOKE EVACUATOR
BOVIE MEDICAL CORPORATION
FSSEP
In Commercial Distribution

  • 10607151004801 ()
FSSEP

  • Surgical plume evacuation system
No Description
Hangwei GE Medical Systems Co., Ltd.
NM 615
In Commercial Distribution

  • 00840682139267 ()


  • Stationary gamma camera system
No Description
Hangwei GE Medical Systems Co., Ltd.
5376496-15
In Commercial Distribution

  • 00840682117869 ()


  • Stationary gamma camera system
Gamma Camera System
Ddd-Diagnostic A/S
c.cam Gamma Camera System
In Commercial Distribution

  • 05711665001008 ()

  • Weight: 1350 Kilogram
  • Height: 169 Centimeter
  • Depth: 229 Centimeter
  • Width: 244 Centimeter
9VIR1200

  • Stationary gamma camera system
Bone Packing Mold Size 10 and 12 mm, TL
K2M, INC.
6101-90002
In Commercial Distribution

  • 10888857190870 ()
6101-90002

  • Bone graft packing block
Bone Packing Mold Size 8.5 and 10 mm, AN
K2M, INC.
6101-90000
In Commercial Distribution

  • 10888857190856 ()
6101-90000

  • Bone graft packing block
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5125
In Commercial Distribution

  • 08806395497195 ()
3300-5125

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5124
In Commercial Distribution

  • 08806395497188 ()
3300-5124

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5122
In Commercial Distribution

  • 08806395497164 ()
3300-5122

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5121
In Commercial Distribution

  • 08806395497157 ()
3300-5121

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5120
In Commercial Distribution

  • 08806395497140 ()
3300-5120

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5119
In Commercial Distribution

  • 08806395497133 ()
3300-5119

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5116
In Commercial Distribution

  • 08806395497102 ()
3300-5116

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5115
In Commercial Distribution

  • 08806395497096 ()
3300-5115

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5113
In Commercial Distribution

  • 08806395497072 ()
3300-5113

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5111
In Commercial Distribution

  • 08806395497058 ()
3300-5111

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5109
In Commercial Distribution

  • 08806395497034 ()
3300-5109

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-5107
In Commercial Distribution

  • 08806395497010 ()
3300-5107

  • Spinal fixation plate, non-bioabsorbable
< 1 ... 2 3 4 5 6 ... 57 >