Company Name Brand Name GMDN Term FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-20V
In Commercial Distribution

  • 90814008023847 ()

  • Height: 20 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-475-14V
In Commercial Distribution

  • 90814008023809 ()

  • Height: 14 Millimeter
  • Width: 4.75 Millimeter
  • Depth: 4.75 Millimeter
ACP-475-14V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12V
In Commercial Distribution

  • 90814008023748 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12F
In Commercial Distribution

  • 90814008023625 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3.75mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-375-12F
In Commercial Distribution

  • 90814008023564 ()

  • Height: 12 Millimeter
  • Width: 3.75 Millimeter
  • Depth: 3.75 Millimeter
ACP-375-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-80
In Commercial Distribution

  • 90814008023519 ()

  • Height: 80 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-80

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-68
In Commercial Distribution

  • 90814008023489 ()

  • Height: 68 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-68

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-74
In Commercial Distribution

  • 90814008023441 ()

  • Height: 74 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-74

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-62
In Commercial Distribution

  • 90814008023403 ()

  • Height: 62 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-62

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-51
In Commercial Distribution

  • 90814008023359 ()

  • Height: 51 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-33
In Commercial Distribution

  • 90814008023298 ()

  • Height: 33 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-2-33

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 1 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-1-34
In Commercial Distribution

  • 90814008023281 ()

  • Height: 34 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-1-34

  • Intervertebral-body internal spinal fixation system
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-171-NS
In Commercial Distribution

  • 00650551148739 ()


  • Depth electrode
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-170-NS
In Commercial Distribution

  • 00650551148722 ()


  • Depth electrode
PLATINUM sEEG ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-169-NS
In Commercial Distribution

  • 00650551148715 ()


  • Depth electrode
one.click is a mechanical auto-injector which automatically administers a pre-set dose of Saizen (somatropin [rNDA origin]) in cartridges.
EMD SERONO, INC.
U1222402
In Commercial Distribution

  • 04054839025792 ()


  • Cartridge-accepting autoinjector, mechanical
PACKING STATION EX0818003 GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0818003
In Commercial Distribution

  • 00763000216948 ()


  • Bone graft packing block
STATION EX0220045 GRAFT PACKING
MEDTRONIC SOFAMOR DANEK, INC.
EX0220045
In Commercial Distribution

  • 00763000371777 ()


  • Bone graft packing block
microTargeting(TM) Electrode, shielded, tungsten, nonsterile, 6x
FHC, INC.
MTSWBN(LX1)-00488
In Commercial Distribution

  • 10873263004880 ()
  • 00873263004883 ()

  • Outer Diameter: 1.24 Millimeter
  • Impedance: Megaohms
  • Length: 50 Millimeter
  • Length: 193 Millimeter
  • Length: 49 Millimeter
  • Length: 246 Millimeter
MTSWBN(LX1)

  • Depth electrode
microTargeting(TM) Electrode, shielded, platinum, DZAP(L), nonsterile, 6x
FHC, INC.
MTSPLN(RD1)-00486
In Commercial Distribution

  • 10873263004866 ()
  • 00873263004869 ()

  • Length: 216 Millimeter
  • Length: 163 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 1.24 Millimeter
  • Length: 50 Millimeter
  • Length: 49 Millimeter
MTSPLN(RD1)

  • Depth electrode
microTargeting(TM) Electrode, shielded, platinum, non-sterile, 6x
FHC, INC.
MTSPBN(LX1)-00482
In Commercial Distribution

  • 10873263004828 ()
  • 00873263004821 ()

  • Length: 193 Millimeter
  • Length: 50 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 1.24 Millimeter
  • Length: 49 Millimeter
  • Length: 246 Millimeter
MTSPBN(LX1)

  • Depth electrode
microTargeting(TM) Electrode, shielded, platinum, nonsterile, 6x
FHC, INC.
MTSPAN(RD1)-00475
In Commercial Distribution

  • 10873263004750 ()
  • 00873263004753 ()

  • Length: 163 Millimeter
  • Impedance: Megaohms
  • Length: 49 Millimeter
  • Length: 216 Millimeter
  • Length: 50 Millimeter
  • Outer Diameter: 1.245 Millimeter
MTSPAN(RD1)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), nonsterile
FHC, INC.
MTDWZN(BP)(BP8)-00439
In Commercial Distribution

  • 10873263004392 ()
  • 00873263004395 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 263.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 3 Millimeter
MTDWZN(BP)(BP8)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), nonsterile
FHC, INC.
MTDWZN(AR)(AR1)-00431
Not in Commercial Distribution

  • 10873263004316 ()
  • 00873263004319 ()

  • Outer Diameter: 0.55 Millimeter
  • Length: 3 Millimeter
  • Impedance: Megaohms
  • Length: 268.5 Millimeter
  • Length: 276.5 Millimeter
MTDWZN(AR)(AR1)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(LS)(LS3)-00386
In Commercial Distribution

  • 10873263003869 ()
  • 00873263003862 ()

  • Length: 291.5 Millimeter
  • Length: 273.5 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
MTDWBN(LS)(LS3)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, non sterile
FHC, INC.
MTDWBN(BP)(BP6)-00382
In Commercial Distribution

  • 10873263003821 ()
  • 00873263003824 ()

  • Length: 227 Millimeter
  • Length: 277 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
MTDWBN(BP)(BP6)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(BP)(BP5)-00380
In Commercial Distribution

  • 10873263003807 ()
  • 00873263003800 ()

  • Length: 215 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 265 Millimeter
  • Outer Diameter: 0.77 Millimeter
MTDWBN(BP)(BP5)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWBN(AO)(AO1)-00372
In Commercial Distribution

  • 10873263003722 ()
  • 00873263003725 ()

  • Length: 282 Millimeter
  • Outer Diameter: 1.27 Millimeter
  • Impedance: Megaohms
  • Length: 3 Millimeter
  • Length: 274 Millimeter
MTDWBN(AO)(AO1)

  • Depth electrode
microTargeting(TM) electrode, back loaded, non sterile, specify impedance, platinum/iridium, glass insulated
FHC, INC.
MTBPXN(EN3)-00307
In Commercial Distribution

  • 10873263003074 ()
  • 00873263003077 ()

  • Length: 40 Millimeter
  • Length: 280 Millimeter
  • Outer Diameter: 0.63 Millimeter
MTBPXN(EN3)

  • Depth electrode
microTargeting(TM) Electrode, back loaded, non sterile, platinum/iridium, glass insulated
FHC, INC.
MTBPBN(KB1)-00302
In Commercial Distribution

  • 10873263003029 ()
  • 00873263003022 ()

  • Length: 30 Millimeter
  • Length: 305 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.63 Millimeter
MTBPBN(KB1)

  • Depth electrode
< 1 2 3 4 5 ... 81 >